My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2025 12:42:52 PM
Creation date
1/22/2025 1:55:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231746
PE
2361 - UST FACILITY
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905032
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
880 E VICTOR RD LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 1 O A Q U I N Environmental Health Department <br /> Y '_ <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> Marks Fuel&Food Inc. 209 369-0958 September 17. 2024 <br /> Facility Address: CERS ID: <br /> 880 E VICTOR RD LODI CA 95240 10181491 <br /> Inspection Contact: Title: Phone: <br /> 209 369-0958 <br /> Inspection Type: Program: <br /> Routine 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> 0 Inspection Z Photos ❑x Samples Manish Pahwa Manager <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Felix Ramirez 11/10/2024 Felix Ramirez 2/15/2026 <br /> Service Technician Manufacturer's Training: <br /> VR,7/5/2026; OPW, 3/11/2026;VMI, 11/7/2025 <br /> OUT=Violation R=Repeat violation COS=Corrected on site during inspection <br /> 1 CA Health and Safety 2030021-Facility has a valid Permit to Operate from the CUPA ❑OUT ❑R COS <br /> Code 25284;CCR <br /> 2711(d) <br /> 2 CA Code of Regulations 2010010-Complete and accurate UST Operating Permit Application has been submitted. ■OUT ❑R o COS <br /> 2711 <br /> 3 CA Code of Regulations 2010013-Facility has submitted a complete and accurate UST Monitoring Plan. ❑OUT o R ❑COS <br /> 2632(d)(1),2634(d) <br /> 4 CA Code of Regulations 2010014-Facility has submitted a complete and accurate UST Response Plan. o OUT o R ❑COS <br /> 2632(d)(2),2634(e) <br /> 5 CA Code of Regulations 2030041-A current facility plot plan is maintained and has been submitted ■OUT o R o COS <br /> 2632(d),2641(h) <br /> 6 CA Health and Safety 2010006-Owner/Operator has not made false statements,certifications,or representations on ❑OUT ❑R o COS <br /> Code 25299(a)(8), documents <br /> 25299(b)(7) <br /> 7 CA Code of Regulations 2010003-Owner/Operator submitted DO form and/or informed the CUPA of any change(s)within ❑OUT o R o COS <br /> 2715(a)(1)(B),2715(a) 30 days(TCR 10) <br /> (3) <br /> 8 CA Code of Regulations 2010016-"Underground Storage Tank Statement of Understanding and Compliance Form" ❑OUT ❑R ❑COS <br /> 2715(a)(1)(A),2715(a) submitted(TCR 10) <br /> (2) <br /> 9 CA Code of Regulations 2030002-Leak detection equipment tested by qualified service technician every 12 months(TCR o OUT o R ❑COS <br /> 2638,26410),2715(f) 9d) <br /> 10 CA Code of Regulations 2030074-Annual Monitoring System Certification Form to the CUPA within 30 days of completion of o OUT ❑R o COS <br /> 2638(c),2638(d) the test <br /> 11 CA Code of Regulations 2030048-Sec containment testing conducted per requirements&records kept for 36 mths(TCR ❑OUT ❑R ❑COS <br /> 2637(a-d),2712(b)(1) 9d) <br /> (F) <br /> 12 ICA Code of Regulations 2010009-Secondary containment test results submitted to the CUPA within 30 days after the test. ❑OUT ❑R ❑COS <br /> 2637(e),2637(f) <br /> 13 ICA Code of Regulations 2010017-Spill bucket testing results submitted to the UPA within 30 days of testing ❑OUT ❑R o COS <br /> 2637.1(d),2637.1(e) <br /> 14 �CA Code of Regulations 2010018-Overfill prevention equipment inspection report form submitted to the UPA within 30 days ❑OUT ❑R ❑COS <br /> 2637.2(d&e), <br /> 2665(a&b) <br /> 15 ICA Code of Regulations 2030042-Line integrity test completed on DW press piping every 12 mths if no fail safe/+ o OUT o R o COS <br /> 2636(f)(3),2643(c)(3) shutdown(TCR 9d) <br /> 16 CA Code of Regulations 2030050-0.1 gph piping test conducted on SW suction systems every 36 mths and after piping o OUT o R o COS <br /> 2643(d),2661(1) repair(TCR 9d) <br /> FA0003862 PR0231746 SCO01 09/17/2024 <br /> EHD Rev.12/06/2021 Page 1 of 5 CP22-UST FULL OUR <br /> 1868 E Hazelton Avenue l Stockton. California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />