My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
14900
>
2800 - Aboveground Petroleum Storage Program
>
PR0516677
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2025 2:15:10 PM
Creation date
1/28/2025 1:59:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0516677
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0000527
FACILITY_NAME
Yogi Bear's Jellystone Park
STREET_NUMBER
14900
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242-9514
APN
05503018
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
14900 W STATE ROUTE 12 LODI 95242-9514
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />December 04, 2024 <br /> Facility Address: <br /> 14900 W HWY 12 , LODI <br /> Facility Name: <br /> Yogi Bear's Jellystone Park <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.3, 112.6 4010057 - SPCC plan has been prepared that meets all applicable <br />requirements. <br />OBSERVATION: The facility failed to prepare an SPCC Plan that meets all applicable requirements. <br />- The SPCC plan fails to follow an accurate cross reference <br />- The facility diagram does not show the location of all Bulk oil containers that are mentioned in the SPCC plan, the <br />55-gallon drums are not indicated in the diagram. <br />REGULATION GUIDANCE: 25270.4.5 (a) Except as provided in subdivision (b), the owner or operator of a storage tank <br />at a tank facility subject to this chapter shall prepare a spill prevention control and countermeasure plan applying good <br />engineering practices to prevent petroleum releases using the same format required by Part 112 (commencing with <br />Section 112.1) of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations, including owners and <br />operators of tank facilities not subject to the general provisions in Section 112.1 of those regulations. An owner or <br />operator specified in this subdivision shall conduct periodic inspections of the storage tank to ensure compliance with <br />Part 112 (commencing with Section 112.1) of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. <br />In implementing the spill prevention control and countermeasure plan, an owner or operator specified in this subdivision <br />shall fully comply with the latest version of the regulations contained in Part 112 (commencing with Section 112.1) of <br />Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. 112.3: The owner or operator or an onshore <br />or offshore facility subject to this section must prepare in writing and implement a Spill Prevention Control and <br />Countermeasure Plan in accordance with § 112.7 and any other applicable section of this part. <br />CORRECTIVE ACTION: Ensure that facility's SPCC plan meets all applicable requirements. Submit proof of correction <br />to the EHD <br />This is (Minor) Violation. <br /> 2 <br />Code of Fed Regulations 112.3 4030038 - SPCC has been implemented. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan was not implemented, as required. <br />Section 5.2.8 of SPCC plan mentions that the overfill prevention system must be tested monthly and yearly. Despite <br />this, the inspection checklist that is completed monthly and yearly only has 2 questions addressing overfill and on <br />multiple inspections the inspector responds with "N/A". Additionally, Patrick Glover was asked how the overfill <br />prevention system is tested according to this section and an answer could not be provided. <br />Section 4.5a of SPCC plan says Appendix I contains the discharge response equipment inventory but it was found in <br />Appendix A. It is also mentioned in this section that the inventory will be inspected monthly but in Appendix A the last <br />inspection was done on 5/23/23. Lastly, the remaining inventory inspections were later found to be located with the <br />monthly aboveground inspections. <br />Section 4.7.2 indicates that Appendix C of SPCC Plan is where the monthly and yearly inspections are located . <br /> 3 <br />FA0000527 PR0516677 SC001 12/04/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 9 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.