My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2026 8:42:57 PM
Creation date
2/3/2025 11:06:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231873
PE
2361 - UST FACILITY
FACILITY_ID
FA0003956
FACILITY_NAME
AT&T CALIFORNIA - UE058
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
10 E 12TH ST TRACY 95376
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Monitoring System Certification Form <br /> 8. IN-TANK GAUGING TESTING <br /> ❑ Check this box if tank gauging is used only for inventory control. <br /> ❑ Check this box if NO tank gauging equipment is installed. Yes No NA <br /> (Do not complete this section if either box is checked.) <br /> All wiring has been: 1) visually inspected for kinks, breaks and proper entry and ❑✓ ❑ ❑ <br /> termination; and 2) tested for ground faults? <br /> Were all in-tank gauging probes visually inspected for damage and residue buildup ❑✓ ❑ ❑ <br /> to ensure that floats move freely, functionally tested, and confirmed operational? <br /> Was accuracy of system's product level readings tested? ❑✓ ❑ ❑ <br /> Was accuracy of system's water level readings tested? ❑✓ ❑ ❑ <br /> Were all probes reinstalled properly? ❑✓ ❑ ❑ <br /> Were all items on the equipment manufacturer's maintenance checklist completed? ❑✓ ❑ ❑ <br /> Probe ID Probe Model Tanks Monitored Pass Fail <br /> T1 847390-107/628026 UE058U002 Diesel ❑✓ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> 9. COMMENTS <br /> Describe all answers marked "No" or "Fail" and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> The L3 sensor for the piping sump was tested.The 794380-208 sensor correctly showed "fuel alarm"when introduced into liquid. But <br /> after testing the sensor, it wouldn't come out of"fuel alarm." I wasn't able to get access into the electrical junction box while I was on <br /> site.This sensor needs to be replaced before the sensor will come out of alarm. The monitor is currently showing"13 fuel alarm." <br /> Backup battery voltage reading at 3.70 volts. <br /> Page 5 of 6 <br />