My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2026 8:42:57 PM
Creation date
2/3/2025 11:06:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231873
PE
2361 - UST FACILITY
FACILITY_ID
FA0003956
FACILITY_NAME
AT&T CALIFORNIA - UE058
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
10 E 12TH ST TRACY 95376
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TAI T <br /> ..r_6 rp I"Z...4 b�M 701 N.?a rkemn"r Orlw.Sams Ana,CA 9270E <br /> pt7141560191U www.%Wl.com <br /> Identification of Test Proceduresfor Secondary Containment Testing <br /> To Whom It May Concern: <br /> Tait Environmental Services, Inc., utilizes the following procedureswhen conducting Secondary <br /> Containment Testing: <br /> 1) Containment Sumps,Transition Sumps, UDCs—Tait follows PD-RP1200-17 Section 6.6 for the <br /> accelerated test method. Tait uses the Incon TS-1000 hydrostatic test equipment following the <br /> attached procedures. <br /> 2) Spill Buckets; Direct Bury& Contained in Sumps—dill buckets contained in sumpsare tested <br /> per PD-1200-17, Section 6.2, however Tait Pass/Fail threshold is0" drop in one hour. Direct Bury <br /> pill Buckets are test the same as containment sumps per PD-1200-17, Section 6.6. <br /> 3) Tank Annular Space—testing isconducted per PD-1200-17, Section 4.2 <br /> 4) Piping Secondary Containment—Testing is conducted per PD-RP1200-17, Section 5.3 <br /> Please consider this letter as our Test Procedure utilized when conducting Secondary Containment <br /> Testing in lieu of either parts or the whole RP1200 document due to copyright infringement. <br />
The URL can be used to link to this page
Your browser does not support the video tag.