My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 8:35:14 AM
Creation date
2/13/2025 10:49:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231604
PE
2361 - UST FACILITY
FACILITY_ID
FA0000650
FACILITY_NAME
GAS AND SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1002 FRONTAGE RD RIPON 95366
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> verl~ili Prevention Equipment Inspection Report <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID Torre OPE per column) � - --- regular super <br /> Are both vent and teak riser piping Yes 71 Yes Yes L7 Yes <br /> e and rily contained? Ki No Lx No No 1L7 No <br /> OPE Model OPW 61 SO I QPW 71$O <br /> What is the OPE response when Shut off Shut off S� ut off L Shut oft <br /> activated? Flow Flow Flow Flow <br /> (Check alf thal'apply-) R Restricts Restricts L7 Restricts TI Restricts <br /> Flow Flow Flow Flow <br /> E. Audible L7 Audible rs' Audible 1] Audible <br /> Alarm Alarrrl Alarm Alarm <br /> L Visual Visual L Visual visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping Yes' r, Yes Yes' ri Yes* <br /> that may interfere with the OPE operatlon7 No No No No ' <br /> At what level in the tank is the OPE set to <br /> activate? !riches from bottom of lark 90.7 " 91.1 5" <br /> What is the percent capacity of the tank at <br /> which the OPE activates" 85% 8 % <br /> Is the OPE in proper operating condition to IrL Yes Yes Yes' L Yes' <br /> respond when the stored substance T No No Irl No No <br /> reaches the designated regulatory level? <br /> 7. SUMMARY of TESTING RESULTS <br /> Pass : Pass I I Pass Pass <br /> OPE Inspection Results C pall Faiii 1 11 Fail L7 Fail <br /> a. COMMENT _ <br /> Describe alf answers fnarkCed ` o"Or+"Fai1°and proposed ramrod}. <br /> Lost atf moo}toring equipmeru either replaced or repaired <br /> * Mark here if <br /> r Flow restrictors interfere with overfill prevention and equipment repairs required <br /> Additional copies of this page may be attacrev. <br /> AHach tank chart(s). rrreasumments, calculations, and In-Ta17k Serop report(s) <br /> Page 2 of <br />