My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2026 2:08:01 PM
Creation date
2/20/2025 11:03:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0522448
PE
2371 - UST FACILITY - 1702 COMPLIANT
FACILITY_ID
FA0015274
FACILITY_NAME
KESAR PETROLEUM INC
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
717 W EIGHTH ST STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KESAR PETROLEUM INC 1717 W EIGHTH ST, STOCKTON TNovember 26, 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 11 CA Code of Regulations 2637(a-d), 2712(b)(1)(F) 2030048 - Sec containment testing conducted per requirements & <br /> records kept for 36 mths (TCR 9d) <br /> OBSERVATION: Secondary containment testing was previously performed on 2/25/25. Testing was due by April 2024. <br /> REGULATION GUIDANCE: Secondary containment testing is required to be performed once every 36 months. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing is performed in a timely manner. The next due <br /> date is April 2027. <br /> This is a Repeat(Class 2)Violation. <br /> 52 CA Code of Regulations 2635(c)(1) 2030036 - Overfill prevention system has not been overridden and meets overfill <br /> requirements (TCR 9b) <br /> OBSERVATION: Overfill prevention testing was last performed on 5/30/25. The testing was due by October 2024. <br /> REGULATION GUIDANCE: Overfill prevention equipment inspections were required to be conducted by October 13, <br /> 2018, and every 36 months thereafter, and within 30 days of completion of a repair. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing is performed in a timely manner. The next due <br /> date is October 2027. <br /> --------------------------------------------------------------- <br /> OBSERVATION: The 87, 91, and Diesel tanks did not have an overfill prevention system. <br /> REGULATION GUIDANCE: All underground storage tanks shall be equipped with an overfill prevention system that does <br /> not allow for manual override and meets one of the following requirements: 1. Alert the transfer operator when the <br /> tank is 90 percent full by restricting the flow into the tank or triggering an audible and visual alarm; or 2. Restrict <br /> delivery of flow to the tank at least 30 minutes before the tank overfills, provided the restriction occurs when the tank is <br /> filled to no more than 95 percent of capacity; and activate an audible alarm at least five minutes before the tank overfills; <br /> or 3. Provide positive shut-off of flow to the tank when the tank is filled to no more than 95 percent of capacity; or, <br /> 4. Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the tank are exposed to <br /> product due to overfilling. <br /> CORRECTIVE ACTION: The permit to install the drop tube with shut-off valves was approved on 9/25/25. Pending <br /> installation. <br /> This is a Repeat(Class 2)Violation. <br /> 59 CA Code of Regulations 2712(b)(1-2) 2030001 - Records of release detection monitoring and maintenance properly <br /> maintained (TCR 9d) <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br /> - 12/20/24 Spill Container test results for the repaired 87 spill container <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; <br /> (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings <br /> of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings <br /> and reconciliations. <br /> CORRECTIVE ACTION: This was corrected on site. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 5 of 6 FA0015274 PRO522448 4582012 11/26/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.