My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
7707
>
2800 - Aboveground Petroleum Storage Program
>
PR0538333
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:19:11 AM
Creation date
2/24/2025 11:18:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0538333
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0021992
FACILITY_NAME
CDCR-California Health Care Facility
STREET_NUMBER
7707
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
Stockton
Zip
95215
APN
181-100-11
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
7707 Austin RD Stockton 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />September 25, 2024 <br /> Facility Address: <br /> 7707 Austin RD, Stockton <br /> Facility Name: <br /> CDCR-California Health Care Facility <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />-Six 105 gallon generators containing motor oil <br />REGULATION GUIDANCE: (3) Describe in your Plan the physical layout of the facility and include a facility diagram, <br />which must mark the location and contents of each fixed oil storage container and the storage area where mobile or <br />portable containers are located. The facility diagram must identify the location of and mark as “exempt” underground <br />tanks that are otherwise exempted from the requirements of this part under § 112.1(d)(4). The facility diagram must <br />also include all transfer stations and connecting pipes, including intra-facility gathering lines that are otherwise <br />exempted from the requirements of this part under § 112.1(d)(11). <br />CORRECTIVE ACTION: Ensure that the SPCC plan includes a complete facility diagram. Provide proof of correction to <br />the EHD. <br />This is (Class 2) Violation. <br />Code of Fed Regulations 112.7(a)(3)(ii) 4010030 - SPCC adequately addresses discharge prevention measures for <br />routine handling, loading/unloading. <br />OBSERVATION: The SPCC Plan failed to address discharge prevention measures, including procedures for routine <br />handling of products such as loading/unloading and facility transfers within the SPCC plan. Chapter 7.3 titled "Spill <br />Prevention" discusses NCYCC spill prevention "items" but does not discuss CHCF spill prevention "items." In other <br />parts of the plan, the generator area of the CHCF are mentioned but the prevention measures for the other petroleum <br />items were not observed as required in this section. <br />The generators for NCYCC were not observed mentioned in this part of the plan. <br />REGULATION GUIDANCE: The SPCC plan shall include: (ii) Discharge prevention measures including procedures for <br />routine handling of products (loading, unloading, and facility transfers, etc.); <br />CORRECTIVE ACTION: Ensure that the SPCC Plan adequately discusses discharge prevention measures, including <br />procedures for routine handling of products such as loading/unloading and facility transfers. Ensure that the generators <br />at NCYCC are included. Submit proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 17 <br />Code of Fed Regulations 112.7(a)(3)(iv) 4010042 - SPCC Plan addressed countermeasures for discharge discovery, <br />response and cleanup. <br />OBSERVATION 1: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to address the <br />countermeasures for discharge discovery, response, and cleanup. The following was not observed in the plan: <br />1) The CHCF discovery and response procedures for the non generator area petroleum tanks/containers were not <br />listed. The spill control supplies listed referenced the generator area. The "CHCF-Spill Discovery and Response <br />Procedures" section did not discuss the non-generator area petroleum tanks/containers. <br />2) Discharge discovery, response, and cleanup (including information on spill control equipment) was not observed in <br />the plan for all of the tanks/containers in the NCYCC area. This includes responses to the generators located around <br />the NCYCC side. <br />Observation 2: The notification procedure on page 22 is out of date. San Joaquin County of Emergency Services <br /> 18 <br />FA0021992 PR0538333 SC001 09/25/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 7 of 11 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.