My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
18260
>
2800 - Aboveground Petroleum Storage Program
>
PR0544269
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:41:35 PM
Creation date
2/24/2025 2:37:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0544269
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0013586
FACILITY_NAME
Tesla Lathrop
STREET_NUMBER
18260
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
Lathrop
Zip
95330
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
18260 S Harlan RD Lathrop 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />October 17, 2024 <br /> Facility Address: <br /> 18260 S Harlan RD, Lathrop <br /> Facility Name: <br /> Tesla Lathrop <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.3, 112.6 4010057 - SPCC plan has been prepared that meets all applicable <br />requirements. <br />OBSERVATION: The facility failed to prepare an SPCC Plan that meets all applicable requirements. <br />-Section 5.2 of the plan for 112.7(c) refers to 5.6.1 and 5.10.2, which were not found in the plan. 40 CFR 112, 112.7(c) <br />is not addressed. <br />-Section 5.12.4 of the plan cites section 5.3. Section 5.3 did not address 40 CFR 112, 112.8(d)(4). <br />The following 40 CFR 112 sections were not found discussed or found otherwise not meeting applicable requirements: <br />-112.8(c)(8) <br />-112.8(c)(8)(v) <br />-112.8(c)(11) <br />REGULATION GUIDANCE: 25270.4.5 (a) Except as provided in subdivision (b), the owner or operator of a storage tank <br />at a tank facility subject to this chapter shall prepare a spill prevention control and countermeasure plan applying good <br />engineering practices to prevent petroleum releases using the same format required by Part 112 (commencing with <br />Section 112.1) of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations, including owners and <br />operators of tank facilities not subject to the general provisions in Section 112.1 of those regulations. In implementing <br />the spill prevention control and countermeasure plan, an owner or operator specified in this subdivision shall fully <br />comply with the latest version of the regulations contained in Part 112 (commencing with Section 112.1) of Subchapter <br />D of Chapter I of Title 40 of the Code of Federal Regulations. 112.3: The owner or operator or an onshore or offshore <br />facility subject to this section must prepare in writing and implement a Spill Prevention Control and Countermeasure <br />Plan in accordance with § 112.7 and any other applicable section of this part. <br />CORRECTIVE ACTION: Ensure that facility's SPCC plan meets all applicable requirements. Submit proof of correction <br />to the EHD. <br />This is (Minor) Violation. <br /> 2 <br />Code of Fed Regulations 112.3(e)(1) 4010008 - SPCC onsite If facility staffed 4 hrs/day, or at the nearest field office if <br />not so attended. <br />OBSERVATION: A copy of the complete Spill Prevention , Control, and Countermeasure (SPCC) Plan was not <br />maintained onsite at the time of inspection. <br />REGULATION GUIDANCE: (e) If you are the owner or operator of a facility for which a Plan is required under this <br />section, you must: (1) Maintain a complete copy of the Plan at the facility if the facility is normally attended at least <br />four hours per day, or at the nearest field office if the facility is not so attended . <br />CORRECTIVE ACTION: A copy of this plan was printed out during the inspection . This was corrected on site. <br />This is (Class 2) Violation. <br /> 4 <br />Code of Fed Regulations 112.7 4010012 - SPCC in writing, follows code seq/cross ref, good eng practice, mgt <br />approval, items not in place. <br /> 11 <br />FA0013586 PR0544269 SC001 10/17/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 8 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.