Laserfiche WebLink
SYSTEM SET-UP REPORT (Page1) <br /> MASS,DENS IT I N-ThNK SET'UP T 2:PREi1 I UM <br /> SYSTEM SETUP DISABLED _ - _ _ _ _ _ - _ _ _ _ <br /> PRODUCT CODE 2 <br /> MAR 22. 2024 9:11 ANI THERMAL COEFF : .000700 <br /> T 1 :REGULAR TANK DIAMETER 118.30 <br /> FISCAL HEIGHT SECURITY PRODUCT CODE 1 TANK PROFILE 4 PTS <br /> DISABLED THERMAL COEFF : .000700 FULL VOL 7901 <br /> "STEM UNITS INVENTORY ALARMS UNITS TANK DIAIIIETER 118.30 88.7 INCH VOL 6365 <br /> U.S, TANK PROFILE 4 PTS 59.2 INCH VOL 3964 <br /> SYSTEM LANGUAGE FULL VOL 19782 29.6 INCH VOL 1560 <br /> ENGLISH CONFIG: STANDARD 68.7 INCH VOL 16056 <br /> SYSTEI1 DHTE TIME FORMAT MAX OR LABEL: VOLUME 59.2 INCH VOL 9897 <br /> MON DD Y.. 1 HH:MM:SS .M HIGH PRODUCT: % MAX 29.6 INCH VOL 3741 FLOAT SIZE: 4.0 IN. PS <br /> OVERFILL : % MAX WATER MINIMUM 0.000 <br /> ,`HEVRON DELIV NEEDED: o MAX <br /> 1490 SOUTH MAIN ST. LOW PRODUCT : VOLUME FLOAT SIZE: 4.0 IN. PS WATER WARNING 1 .5 <br /> MANTECA CH. 95337 WATER MINIMUM 0.0U0 HIGH WATER LIMIT: 2.0 <br /> WATER ALARM FILTER: LOW <br /> ALARM REDUCTION WATER WARNING 1 .5 <br /> SHIFT TIME 1 DISABLED DISABLED HIGH WATER LIMIT: 2.0 <br /> SHIFT TIME 2 DISABLED WATER ALARM FILTER: LOW MAX OR LABEL <br /> SHIFT TIME 3 DISABLED VOLUME 7901 <br /> SHIFT TIME 4 DISABLED <br /> MAX OR LABEL HIGH PRODUCT <br /> TANK PER TST NEEDED WRN VOLUME 19782 % MA: 95.0 <br /> DISABLED (GALLONS. 7506 <br /> TANK ANN TST NEEDED WRN HIGH PRODUCT <br /> DISABLED % MAX 95.0 OVERFILL LIMIT <br /> (GALLONS) 18793 MHS 90.0 <br /> LINE RE-ENHBLE METHOD (GALLONS) 7111 <br /> PASS LINE TEST OVERFILL LIMIT <br /> % MAX 90.0 DELIVERY LIMIT <br /> LINE PER TST NEEDED WRN COMMUNICATIONS SETUP tGALLONSI 17604 MAX 10.0 <br /> DISABLED o - - - - - - - - - - - - {GALLONS) 790 <br /> LINE ANN TST NEEDED WRN <br /> DISABLED DELIVERY LIMIT <br /> MAX 1 CI.0 LOW PRODUCT <br /> PORT SETTINGS: cGALLONS) 1978 VOLUME 500 <br /> PRINT TC VOLUMES <br /> ENABLED COMM BOARD 1 (RS-232) LOW PRODUCT LEAK ALARM LIMIT: 99 <br /> BAUD RHTE 1''00 VOLUME 1000 SUDDEN LOSS LIMIT: 99 <br /> TEMP COMPENSATION PARITY ODD TANK TILT 0100 <br /> VALUE (DEG F ): 60.0 STOP BIT I STOP LEAK ALARM LIMIT: 99 PROBE OFFSET 0.00 <br /> STICK HEIGHT OFFSET DATA LENC,TH: 7 DATA SUDDEN LOSS LIMIT: 99 <br /> DISABLED RS-232 SECURITY TANK TILT 0.00 <br /> ULLAGE: 90% CODE : DISABLED PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS <br /> TO: NONE <br /> H-PROTOCOL DATA FORMAT COMM BOARD : 2 {EDIM ) LINE PIANIFOLDED TtiNKS <br /> HEIGHT RS-232 SECURITY SIPHON NIHNIFOLDED TANKS TO: NONE <br /> PRECISION TEST DURATION CODE : DISABLED TO: NONE <br /> HOURS: 12 LINE MANIFOLDED TANKS <br /> DAYLIGHT SAVING TIPIE TO: NONE LEAK MIN PERIODIC: 0 <br /> DISHBLED AUTO TRAEJSMIT SETTINGS: 0 <br /> RE-DIRE�'T LOCAL PRINTOU <br /> DISABLED AUTO LEHI: ALARM LIMIT LEAK III PERIODIC: 0`, LEAK MIN ANNUAL 0`m <br /> DISABLED 0 0 <br /> EURO PROTOCOL PREFIX AUTO HIGH WATER LIMIT <br /> S DISABLED LEAK MIN ANNUAL 0 <br /> AUTO OVERFILL LIMIT 0 PERIODIC TEST TYPE <br /> DISABLED STANDARD <br /> AUTO LOW PRODUCT <br /> SYSTEM SECURITY DISABLED PERIODIC TEST TYPE ANNUAL TEST FAIL <br /> CODE : 000000 AUTO THEFT LIMIT STANDARD ALARM DISABLED <br /> DISABLED <br /> MAINTENANCE HISTORY AUTO DELIVERY START ANNUAL TEST FAIL PERIODIC TEST FAIL <br /> DISABLED DISABLED ALARM DISABLED ALARM DISABLED <br /> AUTO DELIVERY END <br /> DISABLED PERIODIC TEST FAIL GROSS TEST FAIL <br /> TANK CHART SECURITY AUTO EXTERNAL INPUT ON ALARM DISABLED ALARM DISABLED <br /> DISABLED DISABLED <br /> AUTO EXTERNAL INPUT OFF GROSS TEST FAIL ANN TEST AVERAGING: OFF <br /> DISABLED ALARM DISABLED PER TEST AVERAGING: OFF <br /> CUSTOM ALARMS AUTO SENSOR FUEL HLHRM <br /> DISABLED DISABLED ANN TEST HVERH131 NG: OFF TANK TEST NOTIFY: OFF <br /> AUTO SENSOR IjATER HLHRM PER TEST HVERAGING: OFF <br /> DISABLED TNK TST SIPHON BREHK:OFF <br /> SERVICE NOTICE AUTO SENSOR OUT AL(4,JI TANK TEST NOTIFY: OFF <br /> DISABLED DISABLED DELIVERY DELAY 1 MIN <br /> TNK TST SIPHON BREAK:OFF PUMP THRESHOLD 10.00% <br /> ISO 3166 COUNTRY DELIVERY DELAY 1 MIN <br /> CODE: PUMP THRESHOLD 10.00% <br /> RECEIVER SETUP: <br /> VAPOR MO N I TOR 114E TYPE <br /> CARD ISD NONE <br /> ©2018 Walton Engineering,Inc. <br />