Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> CQUNTY AMENDED <br /> 3/14/2025 <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SYNERGY MARATHON INC 322 S CENTER ST, STOCKTON March 13 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> submitted to the EHD or the California Environmental Reporting System (CERS). <br /> REGULATION GUIDANCE:A copy of the inspection report form must be submitted within 30 days of the test. <br /> CORRECTIVE ACTION: Immediately provide this report to the EHD. <br /> This is (Minor)Violation. <br /> 53 CA Health and Safety Code 25292.2; CCR 2711(a)(11)2010007-Submitted/maintained current Cert of Financial <br /> Responsibility/mech of financial assurance(TCR 11). <br /> OBSERVATION: Current financial responsibility documents were not found on site. <br /> REGULATION GUIDANCE:A copy of current financial responsibility documents are required to be maintained on site. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br /> copy on site. <br /> This is (Minor)Violation. <br /> 56 CA Code of Regulations 2716(a-e)2030013-DO inspections completed at least every 30 days and meet all <br /> requirements(TCR 12). <br /> OBSERVATION:The following were not attached to the designated operator inspection reports: -alarm history <br /> printouts <br /> REGULATION GUIDANCE:The designated operator visual inspection report shall include: -a copy of documentation <br /> demonstrating action taken in response to each compliance issue identified during the previous inspection -a copy of <br /> the alarm history since the previous inspection -a copy of documentation demonstrating action taken in response to <br /> each alarm since the previous inspection -a list of each alarm since the previous inspection for which there is no <br /> documentation of the alarm condition and action taken in response <br /> CORRECTIVE ACTION: Ensure all required documents are attached to future designated operator inspection reports. <br /> This is (Minor)Violation. <br /> 57 CA Code of Regulations 2715(c)2030012-Initial and annual training provided to employees and at least one trained <br /> employee is present. <br /> OBSERVATION:The designated operator employee training for Ahmad Hamid and employee were not performed. <br /> REGULATION GUIDANCE:The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months. The training shall be conducted before the individual <br /> performs the duties of a facility employees.The training shall include, but is not limited to: 1. Operation of the UST <br /> system in a manner consistent with the facility's best management practices 2. Employee's role with regard to <br /> monitoring equipment as specified in the facility's monitoring plan 3. Employee's role with regard to spills and <br /> overfills as specified in the facility's response plan 4. Name of the contact person(s)for emergencies and <br /> monitoring equipment alarms Initial training shall also include a site-specific practical demonstration that provides <br /> both sharing information and evaluating knowledge for responding to emergencies, leak detection, monitoring alarms, <br /> spills and overfills. At least one of the facility employees present during operating hours shall have current training. <br /> FA0012628 PR0516472 SCO01 03/13/2025 <br /> EHD Rev.12/06/2021 Page 6 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />