My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4445
>
2300 - Underground Storage Tank Program
>
PR0231785
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2026 8:45:03 PM
Creation date
3/4/2025 1:24:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231785
PE
2361 - UST FACILITY
FACILITY_ID
FA0003994
FACILITY_NAME
PERSHING GAS FOR LESS
STREET_NUMBER
4445
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11018006
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4445 N PERSHING AVE STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NORCAL TANK 877 BATEMAN WAY <br /> TESTING Galt, CA 95632 <br /> (209) 712-6366 <br /> E.O.VR-203/204 <br /> Vapor Pressure Sensor Verification Test & VST Processor Activation Pressure <br /> Test Report Form <br /> Test Company: NORCAL TANK TESTING <br /> Permit Number:N-633 DATE 6/13/25 877 BATEMAN WAY GALT, CA 95632 <br /> Site Name: PERSHING GAS FOR LESS Technician: David Winkler <br /> Site Address: 4445 N PERSHING Certification Number/Expiration Date <br /> City: STOCKTON CA District: SJV 0082 Select Exp. Date <br /> VST: 11605 10/13/26 <br /> Veeder-Root:B34975 07/21/26 <br /> TEST INFORMATION <br /> Pressure sensor located at dispenser number(s) VENT <br /> Pressure sensor serial number 8459 <br /> Calibration date for digital manometer(must be within 12 months of the test) 511125 <br /> Ending value for digital manometer drift test(must be 0.01 in.w.c. or less) 0 <br /> VAPOR PRESSURE SENSOR UST PRESSURE TEST <br /> UST pressure from digital manometer(in.w.c.) 1.95 <br /> Pressure sensor value from TLS-350(in.w.c.) 1.90 <br /> Is Pressure Value Between-0.20 and+0.20 in.w.c.? PASS <br /> LJVAPOR PRESSURE SENSOR AMBIENT REFERENCE TEST1,2 :1 <br /> Non-calibrated pressure sensor value from TLS-350(in.w.c.) -0.010 <br /> Is pressure value between-0.20 and+0.20 in.w.c.? PASS <br /> VST PROCESSOR ACTIVATION PRESSURE TEST12 <br /> VST processor activation pressure(in.w.c.) NA <br /> Is the VST processor activation pressure:—0.4 in.w.c.? NA <br /> NOTES: 'Valve must be returned to normal operating position after testing is completed. <br /> 'The ambient reference port cap must be in place after testing is completed. <br /> I declare, under penalty of perjury under the laws of the state of California that based on information and belief formed <br /> after reasonable inquiry, the statements and information provided in this document are true, accurate, and complete. <br /> 6/13/25 <br /> Ver. 1.3—12.13.08 <br />
The URL can be used to link to this page