My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2026 8:44:19 PM
Creation date
3/7/2025 11:38:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0506488
PE
2361 - UST FACILITY
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190A
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4943 S STATE ROUTE 99 STOCKTON 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC#32190 4943 S HWY 99 STOCKTON Aril 28 2025 <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 30 CA Code of Regulations 2630(d), 2641(a)2060015-Leak detection equipment located so leak is detected at the <br /> earliest possible opportunity(TCR 9d). <br /> OBSERVATION: Hoses attached to the product piping (flexible)in UDCs 5/6, 7/8, 9/10, and 11/12 were looped upward <br /> and not positioned in a way that leaks will be detected at the earliest opportunity. <br /> REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br /> possible opportunity. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed,trained, and certified contractor to ensure that any <br /> releases in the piping in the UDCs will be detected at the earliest opportunity. <br /> This is a repeat violation (Class 2) Violation. <br /> 49 CA Health and Safety Code 25290.1, 25290.2, 25291 2030047-Secondary containment maintained tight and has <br /> been confirmed by testing. <br /> OBSERVATION:The 91 product piping in UDC 9/10 does not have secondary containment. A portion of the piping was <br /> observed outside the UDC on a side with no deflector plate. <br /> REGULATION GUIDANCE:All underground storage tanks shall be designed and constructed to provide secondary <br /> levels of containment for all hazardous substances released from primary containment. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed,trained, and certified contractor to install secondary <br /> containment under permit and inspection of the EHD, if necessary. <br /> This is (Class 2)Violation. <br /> 51 CA Health and Safety Code 25292.1(a)2030035- UST system is operated to prevent unauthorized release, including <br /> spills and overfills. <br /> OBSERVATION:The fuel filter under dispenser 9/10 on the east side is not located to allow drips and leaks to drain <br /> back into the UDC. No deflector plate was installed on that side of the dispenser. <br /> REGULATION GUIDANCE:The underground storage tank system shall be operated to prevent unauthorized releases. <br /> CORRECTIVE ACTION: Immediately provide approved secondary containment for the filters under permit and <br /> inspection by the EHD, if necessary. <br /> FA0007458 PR0506488 SCO01 04/28/2025 <br /> EHD Rev.12/06/2021 Page 5 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.