SWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br /> printouts from tests(if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br /> 1.FACILITY INFORMATION <br /> Facility Name:CHEVRON 210997(N-4693) Date of Testing: 1/7/2025 <br /> Facility Address: 1442A W COLONY DR.,RIPON,CA 95366 <br /> Facility Contact:Diane Province Phone:209-5990149 <br /> Date Local Agency Was Notified of Testing: 1/7/2025 <br /> Name of Local Agency Inspector(if present during testing):UNKNOWN <br /> 2.TESTING CONTRACTOR INFORMATION <br /> Company Name:TANKNOLOGY INC. <br /> Technician Conducting Test:Jesus Saldivar <br /> Credentials 1: r- CSLB Contractor ICC Service Tech. r- SWRCB Tank Tester r- Other(Specify) <br /> Licensc Number(s): <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used By: Hydrostatic R Vacuum F Other <br /> Test Equipment Used:VACUUM TEST Equipment Resolution:0.1 gph <br /> Spill Box#Tank Spill Box#Tank <br /> Identify Spill Bucket(By Tank T2:REGULARUNLEADED T1:SUPREME UNLEADED Spill Box#Tank DSL Diesel <br /> Number, Stored Product, etc.) REGULAR-Fill 1-Direct- PREMIUM-Fill 1-Direct- -Fill 1-Direct-Grade level Spill Box# <br /> Grade level in containment Grade level in containment <br /> sump sump <br /> r Direct Bury C Direct Bury <br /> Bucket Installation Type: r Direct Bury r Direct Bury (: Contained in Sump C Contained in Sump <br /> C: Contained in Sump (: Contained in Sump <br /> Bucket Diameter: 12.00 <br /> 12.00 12.00 <br /> Bucket Depth: 16.00 <br /> 16.00 16.00 <br /> Wait time between applying <br /> 1 min min <br /> 1 min 1 min <br /> vacuum/water and start of test <br /> Test Start Time(TI): 09:04:00 <br /> 09:00:00 09:02:00 <br /> Initial Reading(RI): 30.00 in.H2O <br /> 30.00 in.H2O 30.00 in.H2O <br /> Test End Time(TF): 09:05:00 <br /> 09:01:00 09:03:00 <br /> Final Reading(Rp): 30.00 in.H2O <br /> 30.00 in.H2O 30.00 in.H2O <br /> Test Duration(TF—TI): 1 min <br /> 1 min 1 min <br /> Change in Reading(RF—RI): 0.00 in.H2O <br /> 0.00 in.H2O 0.00 in.H2O <br /> Pass at Threshold or Criteria: +/-4.00 +/- <br /> +/-4.00 +/-4.00 <br /> Test Result: Pass <br /> Pass AL I Pass <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> CERTIFICATION OF TECIINICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. <br /> Technician's Signature: 41 14L Date: 1/7/2025 <br /> 'State laws and regulations do not currently require testing to be performed by a qualified contractor.However,local requirements may be more stringent. <br /> WO:2375945 <br />