Laserfiche WebLink
SAN JOAQUIN Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: I Facility Address: Date: <br /> AB MARCH LN OPERATIONS INC 11916 E MARCH LN, STOCKTON I November 18, 2025 <br /> 78 2650(e), 2652 2030077-Owner/Operator notified/prepared report upon discovery of unauthorized ❑OUT ❑ R ❑COS <br /> release (TCR 9d) <br /> 79 2717.1(g) 2030045-Red Tag information is legible and has not been removed or tampered ❑OUT ❑ R ❑COS <br /> with <br /> 80 2717.1(f); HSC 25292.3 2030044- Facility did not deposit/allow deposit of petroleum or a hazardous ❑OUT ❑ R ❑COS <br /> (c) substance into a red tagged UST <br /> 81 25292.3(c)(1)(C) 2030079-Facility did not dispense petroleum or a hazardous substance from a ❑OUT ❑ R ❑COS <br /> UST that has been red tagged <br /> 82 2670(b)(e)(f), 2671 2030063- Facility is in compliance with temporary closure requirements ❑OUT ❑ R ❑COS <br /> 83 25298(c); CCR 2670, 2030038- UST system properly closed and complies with permanent closure ❑OUT ❑ R ❑COS <br /> 2672 requirements <br /> 84 25392.4(d), 25292.5(c) 2030066-Repaired/retested any leaks found when ELD testing a UST within 1,000 ❑OUT ❑ R ❑COS <br /> feet of a public water well <br /> 85 2631(a); HSC 25290.1(c) 2060027-Tank system primary containment is constructed, operated, and ❑OUT ❑ R ❑COS <br /> maintained product-tight. <br /> 86 2631.1, 2660(m) 2060024- UST system is made of or lined with materials that are compatible with ❑OUT ❑ R ❑COS <br /> the substance stored. <br /> 87 2631(c), 2662(d) 2060021 -Striker plate installed and positioned correctly. ❑OUT ❑ R ❑COS <br /> 88 2631(b&d), 2666(b&e) 2060007-Primary and secondary containment designed and constructed to an ❑OUT ❑ R ❑COS <br /> engineering specification. <br /> 89 25290.10) 2060008- Enhanced leak detection testing performed before the tank is placed in ❑OUT ❑ R ❑COS <br /> use <br /> 90 2666(b)(2) 2060029-SW piping has been upgraded to continuously monitored DW piping ❑OUT ❑ R ❑COS <br /> when replacement or repair needed <br /> 91 25291(e) 2010-Administration/Documentation-General ❑OUT ❑ R ❑COS <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑ R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 47 25290.1(c3), 25290.2(c3) 2030008-Secondary containment installed after July 1, 2003 is free of water <br /> OBSERVATION: Water was found in the 87, 91, and diesel fill sumps. <br /> REGULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the system <br /> by precipitation, infiltration, or surface runoff. <br /> CORRECTIVE ACTION: Corrected on-site. The service technician removed 2.5 gallons of liquid from the 87, 91, and <br /> diesel fill sumps and returned the sensor to its proper location. <br /> Immediately contact a properly licensed, trained, and certified contractor to address the water intrusion into the 87, 91, <br /> and diesel fill sumps under permit and inspection of the EHD. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 4 of 5 FA0018792 PR0527728 4572703 11/18/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />