My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3555
>
2300 - Underground Storage Tank Program
>
PR0231130
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2026 1:00:39 PM
Creation date
3/11/2025 11:51:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231130
PE
2361 - UST FACILITY
FACILITY_ID
FA0002232
FACILITY_NAME
QUIK STOP MARKET #132
STREET_NUMBER
3555
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
07118020
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3555 W HAMMER LN STOCKTON 95219
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SET-UP REPORT (Page 2) <br /> T 3:Premiurn_Unlead OUTPUT RELH'' SETUI <br /> PRODUCT CODE B LIQUID SENSOR SETUP _ - - - - - - - - - - - IN-TANK rtLHkMS <br /> THERMAL COEFF :.000700 - - - - - - - - - - - - T 3:PROBE OUT <br /> TANK DIAMETER 92.00 R 1 :87 S <br /> TANK PROFILE 4 PTS L 1:87 S STP TYPE: LIQUID SENSOR ALMS <br /> FULL VOL 7841 TRI-STATE (SINGLE FLOAT) PUMP CONTROL OUTPUT L 3:FUEL ALARM <br /> 69.0 INCH VOL 6554 CATEGORY : STP SUMP TANK #: 1 L 7:FUEL ALARM <br /> 46.0 INCH VOL 4099 L 8:FUEL ALARM <br /> 23.0 INCH VOL 1585 L 9:FUEL ALARM <br /> L 2:87 N STP LIQUID SENSOR ALMS L10:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 1:FUEL ALARM L 3:SENSOR OUT ALARM <br /> FLOAT SIZE: 4.0 IN. CATEGORY : STP SUMP L 2:FUEL ALARM L 7:SENSOR OUT ALARM <br /> WATER MINIMUM 0.000 L 7:FUEL ALARM L 8:SENSOR OUT ALARM <br /> L 8:FUEL ALARM L 9:SENSOR OUT ALARM <br /> WATER WARNING 0,8 L 3:PRE SUMP L 9:FUEL ALARM L10:SENSOR OUT ALARM <br /> HIGH WATER LIMIT: 1.0 TRI-STATE (SINGLE FLOAT) L10:FUEL ALARM L 3:SHORT ALARM <br /> WATER ALARM FILTER: LOW CATEGORY : STP SUMP L 1:SENSOR OUT ALARM L 7:SHORT ALARM <br /> L 2:SENSOR OUT ALARM L B:SHORT ALARM <br /> L 7:SENSOR OUT ALARM L 9:SHORT ALARM <br /> MAX OR LABEL L 4:87 S ANN L 8:SENSOR OUT ALARM L10:SHORT ALARM <br /> VOLUME 7841 TRI-STATE (SINGLE FLOAT) L 9:SENSOR OUT ALARM <br /> CATEGORY : ANNULAR SPACE L10:SENSOR OUT ALARM ISD SITE ALARMS <br /> HIGH PRODUCT L 1:SHORT ALARM ISD GROSS PRES FAIL <br /> % MAX 95.0 L 2:SHORT ALARM ISD DEGRD PRES FAIL <br /> (GALLONS) 7449 L 7:SHORT ALARM ISD VAPOR LEAK FAIL <br /> L 5:87 N ANL L 8:SHORT ALARM ISD VP PRES FAIL <br /> OVERFILL LIMIT TRI-STATE (SINGLE FLOAT) L 9:SHORT ALARM ISD VP STATUS FAIL <br /> % MAX 90.0 CATEGORY : ANNULAR SPACE L10:SHORT ALARM <br /> (GALLONS) 7057 SMARTSENSOR SETUP <br /> ISD SITE ALARMS - - - - - - - - - - - - <br /> DELIVERY LIMIT ISD GROSS PRES FAIL <br /> % MAX 20 0 L 6:PRE ANL ISD DEGRD PRES FAL s 1 :DISP 1-2 AFM <br /> (GALLONS) 1568 TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL CATEGORY AIR FLOW METER <br /> CATEGORY : ANNULAR SPACE ISD VP PRES FAIL <br /> LOW PRODUCT ISD VP STATUS FAIL s 2:DISP 3-4 AFM <br /> VOLUME 800 CATEGORY AIR FLOW METER <br /> ISD HOSE ALARMS <br /> LEAK ALARM LIMIT: 99 L 7:DISP 1-2 ALL:FLOW COLLECT FAIL 3:DISP 5-6 AFM <br /> SUDDEN LOSS LIMIT: 99 TRI-STATE (SINGLE FLOAT) CATEGORY AIR FLOW (METER <br /> TANK TILT 0.00 CATEGORY : DISPENSER PAN R 2:87 N <br /> PROBE OFFSET 0.00 TYPE: s 4:DISP 7-8 AFM <br /> PUMP CONTROL OUTPUT CATEGORY AIR FLOW METER <br /> TANK #: 2 <br /> SIPHON MANIFOLDED TANKS L 8:DISP 3-4 s 5:DISP 3-4 VAP PRESS <br /> T#: NONE TRI-STATE (SINGLE FLOAT) CATEGORY VAPOR PRESSURE <br /> LINE MANIFOLDED TANKS CATEGORY : DISPENSER PAN IN-TAN): HLARMS <br /> T#: NONE T 2:PROBE OUT s 6:VENT CANISTES <br /> L 9:DISF' 5-6 LIQUID SENSOR ALP'IS CATEGORY VAPOR VALVE <br /> LEAK MIN PERIODIC: 0% L 1:FUEL ALARM s 8:ATM <br /> 0 TRI-STATE (SINGLE FLOAT) L 2:FUEL ALARM CATEGORY ATM P SENSOR <br /> PERIODIC TEST TYPE CATEGORY : DISPENSER PAN L 7:FUEL ALARM <br /> STANDARD L 8:FUEL ALARM <br /> L 9:FUEL ALARM <br /> PERIODIC TEST FAIL L10:FUEL ALARM <br /> ALARM DISABLED L10:DISP 7-8 L 1:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L ':SENSOR OUT ALARM <br /> GROSS TEST FAIL CATEGORY DISPENSER PAN L 7:SENSOR OUT ALARM <br /> ALARM DISABLED L 8:SENSOR OUT ALARM <br /> L 9:SENSOR OUT ALARM <br /> PER TEST AVERAGING: OFF L10:SENSOR OUT ALARM <br /> L 1 :SHORT ALARM <br /> TANK TEST NOTIFY: OFF L 2:SHORT ALARM <br /> L 7:SHORT ALARM <br /> TNK TST SIPHON BREAK:OFF L 8:SHORT ALARM <br /> L 9:SHORT ALARM EVR/ISD SETUP <br /> DELIVERY DELAY 2 MIN L10:SHORT ALARM <br /> PUMP THRESHOLD 10.00°0 <br /> ISD SITE ALARMS <br /> ISD GROSS PRES FAIL EVR TYPE: BALANCE <br /> PUMP SENSOR SETUP ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL BALANCE NOZZLE TYPE <br /> ISD VP PRES FAIL VST <br /> S 1 :87 NORTH <br /> ISD VP STATUS FAIL <br /> VAPOR PROCESSOR TYPE <br /> TANK #: 2 ISD HOSE ALARMS VEEDER-ROOT POLISHER <br /> DISPENSE MODE: ALL:FLOW COLLECT FAIL <br /> MANIFOLDED: ALTERNATE-HT <br /> ACTIVE SWITCHOVER: R 3:PRE UNL ANALYSIS TIMES <br /> ENABLED: YES TYPE: TIME: 10:00 AM <br /> LEAK TEST METHOD THRESHOLD: 0.0 IN. STANDARD DELAY MINUTES: 1 <br /> - - - - - - - - - - - - NORMALLY CLOSED <br /> TEST ON DATE : ALL TANK <br /> DEC 22, 1999 TANK #: 3 <br /> START TIME : DISABLED ACCEPT HIGH ORVR: <br /> ENABLED <br /> TEST RATE :0.20 GAL.Hk <br /> `)URATION : 2 HOURS <br /> TST EARLY STOP:DISABLED <br /> LEAK TEST REPORT FORMAT <br /> NORMAL <br /> ©2018 Walton Engineering,Inc. <br />