Laserfiche WebLink
SAID dOAQUIN <br />COUNTY <br />Environmental Health Department <br />EHD Rev. 12/06/2021 <br />FA0022301 PR0538822 SCO01 09/23/2025 <br />Page 5 of 6 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />CP22 - UST FULL Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />Regional Transportation Center <br />2849 E MYRTLE ST STOCKTON <br />September 23 2025 <br />87 �CA <br />Code of Regulations <br />2060021 - Striker plate installed and positioned correctly. <br />❑ OUT <br />❑ R ❑ COS <br />2631(c), 2662(d) <br />88 <br />CA Code of Regulations <br />2060007 - Primary and secondary containment designed and constructed to an engineering <br />❑ OUT <br />❑ R ❑ COS <br />2631(b&d), 2666(b&e) <br />specification. <br />89 <br />CA Health and Safety <br />2060008 - Enhanced leak detection testing performed before the tank is placed in use <br />❑ OUT <br />❑ R ❑ COS <br />Code 25290.10) <br />90 <br />CA Code of Regulations <br />2060029 - SW piping has been upgraded to continuously monitored DW piping when replacement <br />❑ OUT <br />❑ R ❑ COS <br />2666(b)(2) <br />or repair needed <br />91 <br />CA Health and Safety <br />2010 - Administration/Documentation - General <br />❑ OUT <br />❑ R ❑ COS <br />Code 25291(e) <br />92 <br />2015 - Administrative/Documentation - General Local Ordinance <br />❑ OUT <br />❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />14 <br />CA Code of Regulations 2637.2(d&e), 2665(a&b) 2010018 - Overfill prevention equipment inspection report form <br />submitted to the UPA within 30 days. <br />OBSERVATION: An overfill prevention equipment inspection was performed on 09/23/2024 and a test report was <br />submitted on 12/10/2024, 48 days late. <br />REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the tests. <br />CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed <br />in a timely manner. <br />This is (Minor) Violation. <br />36 <br />CA Health and Safety Code 25290.1(d) 2060023 - System has a mon system that can detect entry of haz sub <br />liquid/vapor, or water into sec contain. <br />OBSERVATION: Rubber seal was found to be missing on the piping inside the diesel transition sump. <br />REGULATION GUIDANCE: The continuous monitoring system shall be maintained to detect the entry of the liquid or <br />vapor phase of the hazardous substance stored in the primary containment into the secondary containment and to <br />detect water intrusion into the secondary containment. <br />CORRECTIVE ACTION: Correct immediately by having a properly licensed, trained, and certified contractor replace <br />the failed component with a functional component (LG 113-x listed, if applicable), and obtain a permit within one <br />business day from the EHD, if needed. <br />This is (Minor) Violation. <br />49 <br />CA Health and Safety Code 25290.1, 25290.2, 25291 2030047 - Secondary containment maintained tight and has <br />been confirmed by testing. <br />OBSERVATION: There are two diesel flex connectors observed above an entrance inside the building does not have <br />secondary containment. <br />REGULATION GUIDANCE: All underground storage tanks shall be designed and constructed to provide secondary <br />levels of containment for all hazardous substances released from primary containment. <br />CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to install secondary <br />containment under permit and inspection of the EHD. <br />EHD Rev. 12/06/2021 <br />FA0022301 PR0538822 SCO01 09/23/2025 <br />Page 5 of 6 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />