A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GREWALS GAS&LIQUOR' 4100 E FREMONT ST, STOCKTON Aril 22 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This was corrected on site. <br /> This is a repeat violation (Class 2) Violation. <br /> 7 CA Code of Regulations 2715(a)(1)(B), 2715(a)(3)2010003-Owner/Operator submitted DO form and/or informed the <br /> CUPA of any change(s)within 30 days(TCR 10). <br /> OBSERVATION:The designated operator identification form in CERS is outdated.The facility's current designated <br /> operator is Nol-Cal Petroleum Tank Testing. <br /> REGULATION GUIDANCE:The owner or operator shall submit a"Designated Underground Storage Tank Operator <br /> Identification Form" no later than 30 days after any change in the designated UST operator(s). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This was corrected on site. <br /> This is a repeat violation (Class 2) Violation. <br /> 8 CA Code of Regulations 2715(a)(1)(A), 2715(a)(2)2010016-"Underground Storage Tank Statement of Understanding <br /> and Compliance Form"submitted (TCR 10). <br /> OBSERVATION:The Underground Storage Tank Statement of Understanding and Compliance Form was not found in <br /> CERS. <br /> REGULATION GUIDANCE:This form must be uploaded to the California Environmental Reporting System (CERS). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov and upload the Underground Storage Tank Statement of Understanding and Compliance <br /> Form for this facility. <br /> This was corrected on site. <br /> This is a repeat violation (Class 2) Violation. <br /> 45 CA Code of Regulations 2636(f)(2)2030025-LLD on DW press piping monitors hrly, detects a 3.0 gph leak, and <br /> restricts/shuts off flow(TCR 9d). <br /> OBSERVATION:The diesel VMI line leak detector failed to detect a leak when tested. <br /> REGULATION GUIDANCE:All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. <br /> CORRECTIVE ACTION: The service technician adjusted the leak detector, retested it, and it passed. <br /> This was corrected on site. <br /> FA0002123 PR0231574 SCO01 04/22/2025 <br /> EHD Rev.12/06/2021 Page 6 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />