Laserfiche WebLink
The Hydrostatic Reservoir Sensor accurately detects fluid level change in the <br /> ,�,, ��•,� ,� Dual-Point Hydrostatic Reservoir <br /> reservoir and interstice of a double wall storage tank. The Dual-Point version is <br /> ideal for high groundwater areas, and can differentiate between a high level alarm <br /> Sensor (Brine-Filled Double-Wall Tank Sensor) condition and a low level alarm condition. If an inner-wall leak occurs,the brine <br /> seeps into the tank triggering a low level alarm. If an outer wall leak occurs,fluid <br /> seeps into the interstice triggering a high level alarm. <br /> 1L� t 0794380 303 <br /> t <br /> Discriminating Level Sensing <br /> Non Discriminating Static Testing <br /> �t Position Sensitive Hydrostatic <br /> ' � `•/ Gas J9 E-15 1/ Green Diesel <br /> Diesel ./ E-85' DEF <br /> L/ Kerosene E-100 ./ Waste Oil <br /> Jet Fuel Bio-Diesel 20 !JF Motor Oil <br /> Aviation Gas / Bio-Diesel 1002 <br /> 1 Single use only (Test per Sensor Operability Guide in E-10 or less) <br /> 2Single use only (Test per Sensor Operability Guide in B-20 or less) <br /> Sensor Interface Modules <br /> Recommended Min. #of Sensor <br /> Console Software Module Part# Module Description #of Modules Inputs per Availability <br /> Gz « per Console <br /> Module <br /> TLS-450PLUS 6.A or Higher Up to 4 — TLS-4xx <br /> (8600 Series) 0332812-001 Universal Sensor Up to 8 — TLS-4xx 16 Sold <br /> p TLS-450 4.A or Higher <br /> Module (USM) w/ opt. TLS-XB Separately <br /> TLS4 (8601 Series) <br /> TLS4i (8601 Series) 0330020 750 Universal Sensor 12 <br /> TLS4B (8601 Series) <br /> 6.A or Higher Input/Output Module 1 Included <br /> (USIOM-AC) <br /> 0330020-751 6 <br /> TLS4c (8601 Series) <br /> TLS-350/R/PLUS 0329358-001 Interstitial Sensor Up to 8 8 Sold <br /> Interface Module Separately <br /> TLS-350J 124/324 or Higher 0329356-003 4 Probe / 4 Sensor 4 Sold <br /> Interface Module Separately <br /> 1 <br /> TLS-300i 0330230-001 4 Probe / 8 Sensor 8 Included <br /> Interface Module <br /> � Normal Float is in the Center position (correct amount of brine in reservoir) <br /> j Low Liquid Brine drops below 1.2" (3cm) <br /> High Liquid Brine rises above 13.13" (33.4cm) <br /> y Sensor Out Sensor not communicating to ATG/Console <br /> • sF,' �m 5 2Y? ""tea d., qa:e'�;` <br /> Operating Principle Reed Switch / Float <br /> Product Activation Low: 1.2" (3cm), High: 13.13" (33.4cm) <br /> Height <br /> Operating Temp -13°F to +1220F (-25•C to +500C) <br /> Dimensions 17.3" (43.9cm) high, 2.5" (6.4cm) diameter <br /> • Standard Cable Length: 12' (3.65m) <br /> Miscellaneous/Notes • Vented riser cap assembly included <br /> • Reservoir solutions: Up to 50% ethylene glycol in water; up to 50% propylene glycol in water; salt brine solution of up to <br /> 30% CaCI. <br />