Laserfiche WebLink
Underground Storage Tank Program Inspection Report <br />Date: <br />December 19, 2025 <br />Facility Address: <br />620 W DR MARTIN LUTHER KING JR BLVD, StocCHARTER WAY SHELL* <br />Facility Name: <br />Environmental Health Department <br />62 CCR 23 CCR 16 2650(e), <br />2652; HSC 6.7 25295(a) <br />(1) <br />2030077-Owner/Operator notified/prepared report upon discovery of unauthorized <br />release (TCR 9d) <br />o OUT o R o COS <br />63 CCR 23 CCR 16 2717.1 <br />(g); HSC 6.7 25292.3(c) <br />(2) <br />2030045-Red Tag information is legible and has not been removed or tampered <br />with <br />o OUT o R o COS <br />64 CCR 23 CCR 16 2717.1 <br />(f), HSC 6.7 25292.3(c) <br />2030044-Facility did not deposit/allow deposit of petroleum or a hazardous <br />substance into a red tagged UST <br />o OUT o R o COS <br />65 HSC 6.7 25292.3(c)(1)(C)2030079-Facility did not dispense petroleum or a hazardous substance from a <br />UST that has been red tagged <br />o OUT o R o COS <br />66 CCR 23 CCR 16 2670(b) <br />(e)(f), 2671; HSC 6.7 <br />25298(b) <br />2030063-Facility is in compliance with temporary closure requirements o OUT o R o COS <br />67 CCR 23 CCR 16 2670, <br />2672; HSC 6.7 25298(c) <br />2030038-UST system properly closed and complies with permanent closure <br />requirements <br />o OUT o R o COS <br />68 HSC 6.7 25292.4(d), <br />25292.5(c) <br />2030066-Repaired/retested any leaks found when ELD testing a UST within 1,000 <br />feet of a public water well <br />o OUT o R o COS <br />69 CCR 23 CCR 16 2631(a); <br />HSC 6.7 25290.1(c)(1), <br />25290.2(c)(1), 25291(a) <br />(1) <br />2060027-Tank system primary containment is constructed, operated, and <br />maintained product-tight. <br />o OUT o R o COS <br />70 CCR 23 CCR 16 2631.1, <br />2660(m); HSC 6.7 <br />25290.1(c)(1), 25290.2(c) <br />(1), 25291(a)(1) <br />2060024-UST system is made of or lined with materials that are compatible with <br />the substance stored. <br />o OUT o R o COS <br />71 CCR 23 CCR 16 2631(c), <br />2662(d) <br />2060021-Striker plate installed and positioned correctly.o OUT o R o COS <br />72 CCR 23 CCR 16 2631(b), <br />2631(d), 2666(b)(2), 2666 <br />(e)(2) <br />2060007-Primary and secondary containment designed and constructed to an <br />engineering specification. <br />o OUT o R o COS <br />73 HSC 6.7 25290.1(j)2060008-Enhanced leak detection testing performed before the tank is placed in <br />use <br />o OUT o R o COS <br />74 CCR 23 CCR 16 2666(b) <br />(2) <br />2060029-SW piping has been upgraded to continuously monitored DW piping <br />when replacement or repair needed <br />o OUT o R o COS <br />75 CCR 23 CCR Chapter 16 <br />Multiple Sections; HSC <br />Chapter 6.7 Multiple <br />Sections <br />2010-Administration/Documentation - General o OUT o R o COS <br />76 -2015-Administrative/Documentation - General Local Ordinance o OUT o R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item #Remarks <br />3 CCR 23 CCR 16 2632(d)(1), 2634(d), 2641(h) 2010013-Facility has submitted a complete and accurate UST Monitoring <br />Plan. <br />OBSERVATION: Facility failed to submit a complete and accurate UST Monitoring Plan. <br />- The monitoring plans list float and chains for the UDC’s. Standalone sensors were installed on 5/19/25. <br />CORRECTIVE ACTION: Submit a complete and accurate UST Monitoring Plan on CERS. <br />This is a Repeat (Class 2) Violation. <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 4 of 6EHD - CUPA Inspection Report IS03 <br />CP25 - UST DW <br />12/19/2025FA0003738 PR0231058 4577130