Laserfiche WebLink
SAN JOAQUIN Environmental Health Department <br /> —COUNTY <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO 05450 11617 W FREMONT ST, STOCKTON Julv 2, 2025 <br /> 17 CCR 23 CCR 16 2637(g), 2030064-CUPA was notified within 48 hours prior to testing ❑ OUT ❑ R ❑ COS <br /> 2637.1(f), 2637.2(f), 2638 <br /> (e), 2643(g), 2644.1(a)(4) <br /> 18 CCR 23 CCR 16 2640(e), 2030068-Initial or triennial ELD testing conducted on UST system 1 000'of public ❑ OUT ❑ R ❑ COS <br /> 2644.1; HSC 6.7 25292.4 well <br /> (a), 25292.5(a) <br /> 19 CCR 23 CCR 16 2635(e) 2060001-As-built plans for new installations and/or with the permit application ❑ OUT ❑ R ❑ COS <br /> (8) have been submitted <br /> 20 CCR 23 CCR 16 2632(c) 2030003-Leak detection system maintains continuous monitoring that activates an ❑ OUT ❑ R ❑ COS <br /> (2)(B), 2634(d)(1)(A), audible and visual alarm <br /> 2636(f)(1) <br /> 21 CCR 23 CCR 16 2631(g), 2030016-Annular space of USTs are continuously monitored with an audible and ❑ OUT ❑ R ❑ COS <br /> 2632(c)(2)(A)&(B) visual alarm system (TCR 9d) <br /> 22 CCR 23 CCR 16 2636(f) 2030017-Piping out of UDC is fail-safe/shut down, UDC leak shuts off pump/flow, ❑ OUT ❑ R ❑ COS <br /> (4) or tightness test(TCR 9d) <br /> 23 CCR 23 CCR 16 2636(f) 2030018-DW press piping is monitored with an audible/visual alarm or stops flow ❑ OUT ❑ R ❑ COS <br /> (1), 2666(b)(2) at UDC(TCR 9d) <br /> 24 CCR 23 CCR 16 2638(a), 2030043-Leak detection equipment properly installed, calibrated, operated, and ❑ OUT ❑ R ❑ COS <br /> 26410) maintained (TCR 9d) <br /> 25 CCR 23 CCR 16 2631; 2060005-UST system constructed with a mon system capable of detecting entry ❑ OUT ❑ R ❑ COS <br /> HSC 6.7 25291(b) into secondary containment <br /> 26 CCR 23 CCR 16 2630(d), 2060015-Leak detection equipment located so leak is detected at the earliest ❑ OUT ❑ R ❑ COS <br /> 2641(a) possible opportunity(TCR 9d) <br /> 27 HSC 6.7 25299(a)(9) 2030062-Leak detection equipment has not been tampered with or disabled (TCR ❑ OUT ❑ R ❑ COS <br /> 9d) <br /> 28 CCR 23 CCR 16 2636(f), 2030075-E tank system LLD detects 3 gph leak&restricts/shuts off flow or ❑ OUT ❑ R ❑ COS <br /> 2666(c), 2666(f) activates and/vis alarm (TCR 9d) <br /> 29 HSC 6.7 25290.2(d) 2060022-System has a mon system capable of detecting entry of haz sub or ❑ OUT ❑ R ❑ COS <br /> water into secondary containment <br /> 30 CCR 23 CCR 16 2638(f), 2030034-Tag/sticker on affixed monitoring equipment being certified, repaired, or ❑ OUT ❑ R ❑ COS <br /> 26410) replaced <br /> 31 HSC 6.7 25290.1(e) 2030065-Interstitial space of the UST is under constant VPH monitoring (TCR 9d) ❑ OUT ❑ R ❑ COS <br /> 32 HSC 6.7 25290.1(d) 2060023-System has a mon system that can detect entry of haz sub liquid/vapor, ❑ OUT ❑ R ❑ COS <br /> or water into sec contain <br /> 33 CCR 23 CCR 16 2635(a) 2030009-Cathodic protection is installed/maintained as required, including ❑ OUT ❑ R ❑ COS <br /> (2), 2636(b), 2662(c)(1) required documentation (TCR 9c) <br /> (B), 2712(b)(3) <br /> 34 CCR 23 CCR 16 2636(f) 2060012-LLD installed on pressurized piping system (TCR 9d) OUT ❑ R ❑ COS <br /> (2), 2636(f)(5)(B), 2643(c) <br /> (1), 2666(f); HSC 6.7 <br /> 25290.1(h), 25290.2(g), <br /> 25291(f), 25292(e) <br /> 35 CCR 23 CCR 16 2636(f) 2030025-LLD on DW press piping monitors hrly, detects a 3.0 gph leak, and ❑ OUT ❑ R ❑ COS <br /> (2) restricts/shuts off flow(TCR 9d) <br /> 36 HSC 6.7 25290.1(c)(3), 2030008-Secondary containment installed after July 1, 2003 is free of water ❑ OUT ❑ R ❑ COS <br /> 25290.2(c)(3) <br /> 37 CCR 23 CCR 16 2630(d), 2030040-Secondarily contained piping allows liquid to flow into the sump in the ❑ OUT ❑ R ❑ COS <br /> 2641(a) event of a leak(TCR 9d) <br /> 38 HSC 6.7 25290.1(c), 2030047-Secondary containment maintained tight and has been confirmed by OUT ❑ R ❑ COS <br /> 25290.1(e), 25290.2(c), testing <br /> 25291(a)(2) <br /> EHD-CUPA Inspection Report IS03 Page 2 of 5 FA0003606 PR0231923 4593491 12/30/2025 <br /> a <br /> CP25-UST DW g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />