Laserfiche WebLink
S A J 0 A Q U I Environmental Health Department <br /> Food Program Service Request Inspection Report <br /> Facility Name and Address: Hob Nob, 1114 N Main ST, MANTECA <br /> OBSERVATIONS:Front and back food areas and the rest room are lacking proper base coving. Provide approved coved base <br /> before operating. <br /> "Operator will install Schluter all over the front, back of the house and in the rest room. <br /> "The floor surfaces in all food preparation or packaging areas, open food storage areas, utensil washing areas, refuse storage <br /> areas, janitorial areas, and all restrooms and employee change areas, shall be smooth and of durable construction and <br /> nonabsorbent material which is easily cleaned. These floor surfaces shall be coved at the juncture at the floor and wall with a <br /> three-eighths(3/8)inch minimum radius coving and shall extend up the wall at least four(4)inches. Rubber or vinyl top set <br /> base is not permitted in these areas[CRFC§114268]." <br /> CALCODE DESCRIPTION:The walls/ceilings shall have durable,smooth,nonabsorbent,light-colored,and washable surfaces. All <br /> floor surfaces,other than the customer service areas,shall be approved,smooth,durable and made of nonabsorbent material that is <br /> easily cleanable.Approved base coving shall be provided in all areas,except customer service areas and where food is stored in <br /> original unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143 <br /> (d), 114266, 114268, 114268.1, 114271, 114272) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Name on Food Safety Certificate Expiration Date: <br /> Warewash Chlorine(Cl): ppm Heat: °F Water/Hot Water Ware Sink Temp: 120 °F <br /> Quaternary Ammonia(QA): ppm Hand Sink Temp: °F <br /> FOOD ITEM--LOCATION--TEMP°F--COMMENTS <br /> Prep sink--123'Fahrenheit 1 d reach in cooler/under prep table--Front--39'Fahrenheit <br /> 1 D upright cooler--Back--37'Fahrenheit <br /> NOTES <br /> Consultation inspection. <br /> All commercial grade equipment are moved from previous facility to the new site. <br /> Existing gas water heater is 35,000 BTU supplying hot water to the hand sink, prep sink and 3 comp sink. Minimum requirement <br /> is 27,000 BTU. Existing water heater is meeting the minimum requirement. <br /> New Electric water heater of 2KW will be connected to rest room hand sink and mop sink and it is meeting the minimum <br /> requirement. <br /> Floor existing Epoxy,walls are half way lined with stainless steel sheets and the rest are painted with semi gloss paint, existing <br /> ceiling are approved by Jeff C. <br /> Evidence of correction to be submitted to EHD before processing the new permit. <br /> Dining area will have 22 seats. <br /> PE1624$355 to be paid for the new permit. <br /> Operating permit form to be filled. <br /> AP2401239 SC2160 11/05/2024 <br /> EHD 16-23 Rev.09/16/2020 Page 2 of 3 Food Program Service Request Inspection Report <br />