Laserfiche WebLink
oPauJN c( S A N J O A Q U I N Environmental Health Department <br /> "'.!_=i `' COUNTY Jasjit Kang, REHS, Director <br /> C,41 6 Greatness grows here. Muniappa Naidu,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco,REHS, RDI <br /> Willy Ng, REHS <br /> Steven Shih, REHS <br /> Elena Manzo, REHS <br /> Natalia Subbotnikova, REHS <br /> April 7, 2025 <br /> Steven Schamaun <br /> Teichert Stockton <br /> 120 Frank West Cir <br /> Stockton, CA 95206 <br /> sschamaun@teichert.com <br /> UST RETROFIT— MINOR PLAN CHECK PERMIT APPROVAL <br /> Re: A TEICHERT & SON INC SR2500972 <br /> 120 FRANK WEST CIR, STOCKTON, CA 95206 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br /> application for a minor plan check permit to do the following on the underground storage tank (UST) <br /> system at the above noted address: <br /> • Replace the existing monitoring panel with TLS-450PLUS <br /> • Replace all leak detectors <br /> The minor plan check permit has been approved with the following conditions: <br /> 1. Contact the local fire district, the San Joaquin Valley Air Pollution Control District, and the local <br /> community development department for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Provide written notification to ust(a)-sigov.org for the following repairs and testing (a 48-hour <br /> notice is required). Please be aware: an inspector may not be present for testing. <br /> a. Monitoring system functionality: Functionality of the monitoring system, including all <br /> sensors, must be verified to ensure monitoring has been restored to meet the <br /> requirements of CCR Title 23 and California Health & Safety Code (HSC) Chapter 6.7. <br /> **A copy of the alarm history shall be printed prior to removing the current monitoring <br /> panel, and made available at the time of EHD inspection. <br /> b. Leak detector test: Verify the device can detect a leak of 3 gallons per hour at 10 psi. <br /> Verify line volumes are appropriate for the make and model of the installed leak <br /> detectors. <br /> 4. Any individual performing the work of a service technician must meet the following <br /> qualifications: <br /> a. Possess or be employed by a person who possesses one of several permissible valid, <br /> current contractor's licenses issued by the Contractors State License Board (may be <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/ehd <br />