Laserfiche WebLink
CONFIGURED: ENABLED <br /> CONTROLLING PUMP: Pm 2: 91 <br /> PIPE TYPE: 2/3 inch Fiberglass <br /> 2.0 DIAMETER LENGTH: 340.00 FEET <br /> 3.0 DIAMETER LENGTH: 0.00 FEET <br /> THERMAL COEFFICIENT: 0.000700 <br /> 0.2 GPH LINE LEAK: DISABLED <br /> 0.1 GPH LINE LEAK: DISABLED <br /> SHUTDOWN RATE: 3.0 GAL/HR <br /> LOW PRESSURE SHUTOFF: DISABLED <br /> LOW PRESSURE ALARM LIMIT: 0 psi <br /> CONTINUOUS HANDLE TIMEOUT: 16 HOURS <br /> FUEL OUT LIMIT: 10.00 INCHES <br /> ALTITUDE PRESSURE OFFSET: 0.00 psi <br /> PUMP COMM CONTROL RELAY: NOT ASSIGNED <br /> --- LINE 3 --- <br /> CONFIGURED: ENABLED <br /> CONTROLLING PUMP: Pm 3: Diesel <br /> PIPE TYPE: 2/3 inch Fiberglass <br /> 2.0 DIAMETER LENGTH: 125.00 FEET <br /> 3.0 DIAMETER LENGTH: 0.00 FEET <br /> THERMAL COEFFICIENT: 0.000450 <br /> 0.2 GPH LINE LEAK: DISABLED <br /> 0.1 GPH LINE LEAK: DISABLED <br /> SHUTDOWN RATE: 3.0 GAL/HR <br /> LOW PRESSURE SHUTOFF: DISABLED <br /> LOW PRESSURE ALARM LIMIT: 0 psi <br /> CONTINUOUS HANDLE TIMEOUT: 16 HOURS <br /> FUEL OUT LIMIT: 10.00 INCHES <br /> ALTITUDE PRESSURE OFFSET: 0.00 psi <br /> PUMP COMM CONTROL RELAY: NOT ASSIGNED <br /> -------------------------------------------------------- <br /> *** PUMPS AND LINES - ALL LINES *** <br /> -------------------------------------------------------- <br /> RESTART ON ALARM CLEAR: ENABLED <br /> LINE LOCKOUT SCHEDULE: Disabled <br /> -------------------------------------------------------- <br /> *** PUMPS AND LINES - ALL PLLD *** <br /> -------------------------------------------------------- <br /> LINE RE-ENABLE METHOD: PASS LINE TEST <br /> PERIODIC TEST WARNINGS: DISABLED <br /> DAYS BEFORE PERIODIC WARNING: 25 <br /> DAYS BEFORE PERIODIC ALARM: 30 <br /> ANNUAL TEST WARNINGS: DISABLED <br /> DAYS BEFORE ANNUAL WARNING: 355 <br /> DAYS BEFORE ANNUAL ALARM: 365 <br /> PRECISION TEST DELAY: 12 HOURS <br /> -------------------------------------------------------- <br /> *** INVENTORY SETUP - REPORT TIMES *** <br /> -------------------------------------------------------- <br /> INVENTORY LOG INTERVAL: DISABLED <br /> STORAGE LENGTH: 720 <br /> -------------------------------------------------------- <br /> *** INVENTORY SETUP - SHIFT CLOSE METHOD *** <br /> -------------------------------------------------------- <br /> CLOSE METHOD: TIMED <br /> -------------------------------------------------------- <br /> *** INVENTORY SETUP - SHIFT TIMES *** <br /> -------------------------------------------------------- <br /> --- SHIFT 1 --- <br /> OPENING TIME: 03:00 AM <br />