Laserfiche WebLink
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />February 25, 2025 <br /> Facility Address: <br /> 36 W MATHEWS RD, FRENCH CAMP <br /> Facility Name: <br /> SILVA TRUCKING <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.8(d)(4) 4030026 - Aboveground valves, piping, and appurtenances are regularly <br />inspected. <br />OBSERVATION: The facility failed to regularly inspect aboveground valves, piping, and appurtenances. The catch pans <br />was observed with approximately 2 inches of liquid. The remote fill box was not observed with a lock. A broken lock <br />was observed on the floor next to the remote fill box. No daily, monthly or annual inspection reports were observed <br />during the time of inspection. <br />REGULATION GUIDANCE: (d)(4) Regularly inspect all aboveground valves, piping, and appurtenances. During the <br />inspection, you must assess the general condition of items, such as flange joints, expansion joints, valve glands and <br />bodies, catch pans, pipeline supports, locking of valves, and metal surfaces. <br />CORRECTIVE ACTION: Immediately inspect all required components, including but not limited to the remote fill box, <br />aboveground valves, piping, appurtenances and ensure inspections are done regularly. Provide proof of correction to <br />the EHD. <br />This is (Class 2) Violation. <br /> 69 <br />CA Health and Safety Code 25270.6(a) 4010032 - Tank Facility Statement or Business Plan has been submitted . <br />OBSERVATION: A complete tank facility statement or a business plan has not been submitted . <br />REGULATION GUIDANCE: (a)(1) On or before January 1, annually, each owner or operator of a tank facility subject to <br />this chapter shall file with the statewide information management system, a tank facility statement that shall identify <br />the name and address of the tank facility, a contact person for the tank facility, the total storage capacity of the tank <br />facility, and the location and contents of each petroleum storage tank that exceeds 10,000 gallons in storage <br />capacity. A copy of a statement submitted previously pursuant to this section may be submitted in lieu of a new tank <br />facility statement if no new or used storage tanks have been added to the facility or if no significant modifications have <br />been made. For purposes of this section, a significant modification includes, but is not limited to, altering existing <br />storage tanks or changing spill prevention or containment methods. (2) Notwithstanding paragraph (1), an owner or <br />operator of a tank facility that submits a business plan, as defined in subdivision (d) of Section 25501 , to the <br />statewide information management system and that complies with Sections 25503 , 25505 , 25505.1 , 25507 , <br />25507.2 , 25508 , 25508.1 , and 25508.2 , satisfies the requirement in paragraph (1) to file a tank facility statement. <br />CORRECTIVE ACTION: Immediately submit a complete and adequate tank facility statement or a business plan. <br />Submit proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 74 <br />Code of Fed Regulations 112.20(e) 4010044 - Substantial Harm Criteria certification maintained at the facility as <br />required. <br />OBSERVATION: The facility failed to complete and maintain (at the facility) the Substantial Harm Criteria certification <br />form, and the owner/or operator Dave Silva determined that the facility could not be reasonably expected to cause <br />substantial harm to the environment. The Substantial Harm Criteria certification form was observed without a signed <br />signature. <br />REGULATION GUIDANCE: (e) If the owner or operator of a facility determines pursuant to paragraph (a)(2) of this <br />section that the facility could not, because of its location, reasonably be expected to cause substantial harm to the <br /> 78 <br />FA0009414 PR0516179 SC001 02/25/2025 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 8 of 9 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD