Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SAI GAS AND FOOD 2358 E WATERLOO RD, STOCKTON April 29 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 56 CA Code of Regulations 2716(a-e)2030013-DO inspections completed at least every 30 days and meet all <br /> requirements(TCR 12). <br /> 1)OBSERVATION:The designated operator failed to check and note the correct test dates for the Secondary <br /> Containment on the designated operator inspection reports. The reports listed 3/3/2023 but the correct date is <br /> 3/14/2024.. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of the <br /> required information on the reports. <br /> 2)OBSERVATION:The designated operator failed to check and note all required items on the visual inspection <br /> reports. Multiple reports had compliance issues listed by the DO but the owner/operator did not write any corrective <br /> actions in Section 5 to the compliance issues. <br /> REGULATION GUIDANCE: Owners/Operators shall review reports and note corrective actions in Section 5 <br /> CORRECTIVE ACTION: Ensure all compliance issues noted by the DOS have corrective actions in section 5. <br /> This is a repeat violation (Class 2) Violation. <br /> 58 CA Code of Regulations 2715(c)(3), 2715(c)(4)2010015- Copies of Facility Employee Training Certificates maintained. <br /> OBSERVATION: The Facility Employee Training Certificates for the last 2 years did not have any las names listed for <br /> Deepi <br /> REGULATION GUIDANCE:All site employees must be trained prior to taking responsibility as a facility employee if <br /> after October 1, 2018, or within 30 days of hire if prior to October 1, 2018. The Facility Employee Training Certificate <br /> shall contain accurate information for all employees trained. <br /> CORRECTIVE ACTION: Update the Facility Employee Training Certificate to contain the accurate information and <br /> submit a copy of the updated form to the EHD. <br /> This is (Minor)Violation. <br /> 59 CA Code of Regulations 2712(b)(1-2)2030001 - Records of release detection monitoring and maintenance properly <br /> maintained (TCR 9d). <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br /> -Overfill Prevention Equipment for 11/14/2024 <br /> REGULATION GUIDANCE:These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; <br /> (3)results of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6)results of <br /> inventory readings and reconciliations. <br /> FA0006343 PR0231756 SCO01 04/29/2025 <br /> EHD Rev.12/06/2021 Page 6 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />