COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2026 8:59:38 PM
Creation date
4/29/2025 11:21:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231066
PE
2361 - UST FACILITY
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint Stockton Switch
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
AVE
City
Stockton
Zip
95204
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3807 Coronado AVE Stockton 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - UST FULL Inspection Report <br />Date: <br />October 22, 2025 <br /> Facility Address: <br /> 3807 Coronado AVE, Stockton <br /> Facility Name: <br /> Sprint Stockton Switch <br /> □ OUT □ R □ COS2060008 - Enhanced leak detection testing performed before the tank is placed in useCA Health and Safety <br />Code 25290.1(j) <br /> 89 <br /> □ OUT □ R □ COS2060029 - SW piping has been upgraded to continuously monitored DW piping when replacement <br />or repair needed <br />CA Code of Regulations <br />2666(b)(2) <br /> 90 <br /> □ OUT □ R □ COS2010 - Administration/Documentation - GeneralCA Health and Safety <br />Code 25291(e) <br /> 91 <br /> □ OUT □ R □ COS2015 - Administrative/Documentation - General Local Ordinance 92 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />CA Code of Regulations 2632(d)(1), 2634(d) 2010013 - Facility has submitted a complete and accurate UST <br />Monitoring Plan.. <br />OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br />-The monitoring plan lists the personnel responsible as Darren Reich and Gerald Mercado. Juan Aguilera, Data Center <br />Operations Manager stated that both of these names are out of date. <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br />(CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a repeat violation (Class 2) Violation. <br /> 3 <br />CA Health and Safety Code 25292.2; CCR 2711(a)(11) 2010007 - Submitted/maintained current Cert of Financial <br />Responsibility/mech of financial assurance (TCR 11). <br />OBSERVATION: Current financial responsibility documents have not been submitted to the EHD. The most recent <br />Certificate of Financial Responsibility in CERS is dated 5/14/24 and the copy on site is dated 11/1/23.. The most <br />recent copy of the proof of insurance on site expired 5/1/24. <br />REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/, and upload the required documents. <br />This is a repeat violation (Class 2) Violation. <br /> 53 <br />Overall Inspection Comments: <br />Note: Prior to the start of the monitoring system certification, the technician on site found the programming of the <br />probe in the Veeder Root panel to be incorrect . T alarms for overfill, setup data warning, max product and high <br />product were active but he stated that the annular sensor and sump sensor for the UST system were not affected <br />and were still programmed correctly. The time was also found to be set 2 hours ahead. The technician corrected <br />all programing and ensured all functions related to the UST system were normal on the panel before testing any <br />components of the UST system . <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by November 21, 2025. <br />FA0003819 PR0231066 SC001 10/22/2025 <br />EHD Rev. 12/06/2021 CP22 - UST FULL OIRPage 5 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.