My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1532
>
2300 - Underground Storage Tank Program
>
PR0231522
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2026 12:19:20 PM
Creation date
4/30/2025 1:45:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231522
PE
2361 - UST FACILITY
FACILITY_ID
FA0004051
FACILITY_NAME
UPS - Stockton
STREET_NUMBER
1532
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
AVE
City
Stockton
Zip
95205
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1532 N Broadway AVE Stockton 95205
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTE: EHD does not have record <br /> of this testing being scheduled. EHD Underground Storage Tank <br /> did not witness this during the Monitoring System Certification Form <br /> SR0082977 inspection. CP 7/7/2025 <br /> 7. LINE LEAK DETECTOR TESTING <br /> Q Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) <br /> Simulated release rate verified: (Check all that apply.) Yes No NA <br /> 93 GPH © 0.1 GPH EJ 0.2 GPH <br /> Has the testing apparatus been properly calibrated? ® 0 0 <br /> For emergency generator tank systems, does the LLD create an audible and visual ri ri <br /> alarm when a leak is detected? <br /> For mechanical LLDs, does the LLD restrict the flow through the pipe when a <br /> release is detected? <br /> For electronic LLDs, does the turbine automatically shut off when a release is ri ri <br /> detected? <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the © ri <br /> monitoring system is disabled or disconnected? <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the ri r] <br /> monitoring system malfunctions or fails a tightness test? <br /> For electronic LLDs, have all accessible wiring connections been visually inspected <br /> for kinks and breaks? <br /> Were all items on the equipment manufacturer's maintenance checklist completed? ri Ej <br /> Were all LLDs confirmed operational within regulatory requirements? <br /> LLD /D LLD Model Lines Monitored Pass Fail <br /> T1-87 LD-2000 Regular 87 product ® r] <br /> 0 <br /> Only tested line leak detector 0 <br /> 0 <br /> 0 <br /> © ri <br /> ri 0 <br /> 0 97 <br /> 0 r] <br /> 0 El <br /> 0 1 r <br /> Describe all answers marked "No"or "Fail"and proposed remedy in Section 9. <br /> List all monitoring equipment either replaced or repaired in Section 9 <br /> Page 4 of 6 <br />
The URL can be used to link to this page