Laserfiche WebLink
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />April 03, 2025 <br /> Facility Address: <br /> 15971 S TRACY BLVD, TRACY <br /> Facility Name: <br /> HALEY FLYING SERVICE INC <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.3 4030038 - SPCC has been implemented. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan was not implemented, as required. <br />The SPCC Plan was not certified (signed) by a Professional Engineer, facility diagram was missing, and Monthly <br />Inspection Checklists were not filled out for each individual tank. <br />REGULATION GUIDANCE: 112.3: The owner or operator or an onshore or offshore facility subject to this section must <br />prepare in writing and implement a Spill Prevention Control and Countermeasure Plan (hereafter “SPCC Plan” or <br />“Plan”),” in accordance with § 112.7 and any other applicable section. 25270.4.5.(a): An owner or operator shall <br />conduct periodic inspections of the storage tank to ensure compliance with Part 112 (commencing with Section 112.1) <br />of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. In implementing the spill prevention control <br />and countermeasure plan, an owner or operator shall fully comply with the latest version of the regulations contained in <br />Part 112 (commencing with Section 112.1) of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. <br />CORRECTIVE ACTION: Implement the SPCC plan, as required. Submit proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 3 <br />Code of Fed Regulations 112.3(d) 4010003 - Professional engineer has properly reviewed and certified the SPCC Plan. <br />OBSERVATION: Professional Engineer (PE) failed to properly review and/or certify the Spill Prevention, Control, and <br />Countermeasure (SPCC) plan per the requirements listed in 40 CFR 112.3(d)(1). Signature was missing. <br />REGULATION GUIDANCE: (d) Except as provided in § 112.6, a licensed Professional Engineer must review and certify <br />a Plan for it to be effective to satisfy the requirements of this part . <br />(1) By means of this certification, the Professional Engineer attests: <br />-(i) That he is familiar with the requirements of § 112.3; <br />-(ii) That he or his agent has visited and examined the facility; <br />-(iii) That the Plan has been prepared in accordance with good engineering practice, including consideration of <br />applicable industry standards, and with the requirements of this part; <br />-(iv) That procedures for required inspections and testing have been established; and <br />-(v) That the Plan is adequate for the facility. <br />-(vi) That, if applicable, for a produced water container subject to § 112.9(c)(6), any procedure to minimize the amount <br />of free-phase oil is designed to reduce the accumulation of free-phase oil and the procedures and frequency for <br />required inspections, maintenance and testing have been established and are described in the Plan. <br />CORRECTIVE ACTION: Ensure that the SPCC plan has been appropriately reviewed and certified by a PE; submit <br />proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 5 <br />Code of Fed Regulations 112.7(a)(3), 25270.4.5(a) 4010015 - SPCC contains an adequate facility diagram. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to include a facility diagram. <br /> 16 <br />FA0009326 PR0515798 SC001 04/03/2025 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 7 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD