COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2026 3:10:38 PM
Creation date
5/2/2025 11:16:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0543574
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0024750
FACILITY_NAME
Harney Lane 76
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
141 E HARNEY LN LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANsJOAQUIN Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Harnev Lane 76 1141 E HARNEY LN, LODI TJuly 17, 2025 <br /> 55 CA Code of Regulations 2716(f) 2010004 - Copies of DO inspections for last 12 months maintained, 36 months for <br /> those after 10/1/18 (TCR 12) <br /> OBSERVATION: The 2022, 2023 and 2024 designated operator inspection reports were not found on site. the January <br /> and February DO reports were missing for 2025. <br /> REGULATION GUIDANCE: Designated operator inspection reports prior to October 1, 2018 shall be retained on site for <br /> twelve months. Designated operator inspection reports on or after October 1, 2018 shall be retained on site for thirty-six <br /> months. <br /> CORRECTIVE ACTION: Locate and ensure that copies of the previous thirty-six months of designated operator <br /> inspection reports are maintained on site. <br /> Submit copies of the missing reports to the EHD. <br /> This is a (Minor)Violation. <br /> 57 CA Code of Regulations 2715(c) 2030012 - Initial and annual training provided to employees and at least one trained <br /> employee is present <br /> OBSERVATION: The designated operator employee trainings were not observed onsite. <br /> REGULATION GUIDANCE: The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months. The training shall be conducted before the individual <br /> performs the duties of a facility employees. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms Initial training shall also include a <br /> site-specific practical demonstration that provides both sharing information and evaluating knowledge for responding to <br /> emergencies, leak detection, monitoring alarms, spills and overfills. At least one of the facility employees present during <br /> operating hours shall have current training. <br /> CORRECTIVE ACTION: Ensure that employees have been trained by the designated operator, maintain the list on site, <br /> and submit a copy of the training records to the EHD. <br /> This is a Repeat(Class 2)Violation. <br /> 59 CA Code of Regulations 2712(b)(1-2) 2030001 - Records of release detection monitoring and maintenance properly <br /> maintained (TCR 9d) <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. The following <br /> records were not observed: <br /> - Monitoring System Certification test results for 2022, 2023, and 2024. <br /> - Overfill Prevention Equipment test results performed on 2/20/2025 <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: <br /> (1) date and time of all monitoring or sampling; <br /> (2) monitoring equipment calibration and maintenance records; <br /> (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; <br /> (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results <br /> of inventory readings and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the last <br /> three years on site. <br /> Submit copies of any missing work orders and alarm records to the EHD. <br /> This is a (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 6 of 8 FA0024750 PRO543574 4525860 7/17/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.