Laserfiche WebLink
Underground Storage Tank <br />Secondary Containment Testing Report Form <br />6. TANK SECONDARY CONTAINMENT TEST <br />Test Method Developed by ❑ Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />Test Type ❑ Pressure ❑ Vacuum ❑ Hydrostatic <br />Test Equipment Used: <br />Tank ID <br />1-87 <br />2&3-91-Dsl <br />3-91 <br />4 -91 -Vent <br />Tank Manufacturer <br />XERXES <br />XERXES <br />Ameron <br />Ameron <br />Tank Capacity <br />30K <br />20K 2 Compt <br />9:13 <br />9:16 <br />Test Start Time <br />Exempt <br />Exempt <br />5 Psi <br />5 Psi <br />Initial Reading <br />10:00 <br />10:03 <br />10:13 <br />10:16 <br />Test End Time <br />5 Psi <br />5 Psi <br />5 Psi <br />5 Psi <br />Final Reading <br />0 Psi <br />0 Psi <br />0 Psi <br />0 Psi <br />Change in Reading <br />No Loss <br />No Loss <br />No Loss <br />No Loss <br />Pass/Fail Criteria <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />Tightness Test Results <br />❑ Pass ❑ Fail <br />I ❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />I ❑ Pass ❑ Fail <br />7. PIPE SECONDARY CONTAINMENT TEST <br />Test Method Developed by ❑ Manufacturer ® Industry Standard ❑ Professional Engineer <br />Test Type ® Pressure ❑ Vacuum ❑ Hydrostatic <br />Test Equipment Used: Pressure Gauges in Psi/Nitrogen <br />Pipe Run ID <br />1-87 <br />2 -87 -Vent <br />3-91 <br />4 -91 -Vent <br />Pipe Manufacturer <br />Ameron <br />Ameron <br />Ameron <br />Ameron <br />Test Start Time <br />9:00 <br />9:03 <br />9:13 <br />9:16 <br />Initial Reading <br />5 Psi <br />5 Psi <br />5 Psi <br />5 Psi <br />Test End Time <br />10:00 <br />10:03 <br />10:13 <br />10:16 <br />Final Reading <br />5 Psi <br />5 Psi <br />5 Psi <br />5 Psi <br />Change in Reading <br />0 Psi <br />0 Psi <br />0 Psi <br />0 Psi <br />Pass/Fail Criteria <br />No Loss <br />No Loss <br />No Loss <br />No Loss <br />Tightness Test Results <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />Pipe Run ID <br />5 -Diesel <br />6-Dsl Vent <br />7 -Gas Vapor <br />Pipe Manufacturer <br />Ameron <br />Ameron <br />Ameron <br />Test Start Time <br />9:20 <br />9:23 <br />9:05 <br />Initial Reading <br />5 Psi <br />5 Psi <br />5 Psi <br />Test End Time <br />10:20 <br />10:23 <br />10:05 <br />Final Reading <br />5 Psi <br />5 Psi <br />5 Psi <br />Change in Reading <br />0 Psi <br />0 Psi <br />0 Psi <br />Pass/Fail Criteria <br />No Loss <br />No Loss <br />No Loss <br />Tightness Test Results <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Additional copies of this page may be attached. <br />All tests marked "Fail" and any repairs made before or during the tightness test must be described in <br />the COMMENTS section. <br />Page 2 of 5 <br />