My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2026 8:36:04 PM
Creation date
5/5/2025 11:39:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231897
PE
2361 - UST FACILITY
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2375 N TRACY BLVD TRACY 95376
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN <br /> J O A U I Environmental Health Department <br /> COUNTY <br /> Grrarness grows hare, <br /> Service Request Inspection Report <br /> Name of Facility: ELITE FUELS Date: 09/24/2025 <br /> Address: 2375 N TRACY BLVD , TRACY 95376 <br /> Requestor: Telephone: ()- <br /> Program Element: 2308- UST RETROFIT Request#: SR2501487 <br /> Inspection Type: 998-OT UST RETROFIT/REPAIR PLN CHCK/INSPECTION <br /> Onsite Service Technician: Marco Alejos ICC Service Tech/Installer Exp. Date: 2/28/2028 <br /> Manufacturer training: Universal, 11/22/27 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> Observed at time of inspection: <br /> 1) calculations for 95% shutdown measurement of the UST waste oil overfill valve for the used oil tank. <br /> 2) tank chart used for calculations was the Owens Corning Model D-5 550 gallon tank. <br /> 3) verified overfill functionality <br /> 4) The red tag of the used oil tank was verified as intact at the time of inspection. No tampering was observed. <br /> 5) The red tag of the used oil tank has been removed. The volume of the tank at the time of removal was 5.5 inches of used oil <br /> from the bottom of the tank. <br /> Please be aware that any reinstallation of the used oil overfill device, including immediately following hazardous waste pickup <br /> activities(used oil pumping), must be conducted by a properly certified service technician. <br /> Please also be aware that the used oil is required to pass through a wire mesh before it enters through the overfill device. Per Nik <br /> Zagarov,the funnel attachment contains a mesh the used oil can pass through as it enters into the tank. Per the technician on <br /> site,the device filter does not stay attached to the overfill component and the employees will need to attach it prior to use. <br /> Please provide the following statements and documents prior to depositing any used oil <br /> a) A statement that employees will use the attachment as outlined in the installation manual and that they are aware of the <br /> mesh requirements. <br /> b) A copy of the overfill calculations used to determine 95 percent shutdown. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Amin Kahn, Owner <br /> EH Specialist: MONICA DE ANDA Phone: (209)616-3063 <br /> FA0006443 SR2501487 SC998 09/24/2025 <br /> EHD Rev.09/16/2020 Page 1 of 1 Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.