Laserfiche WebLink
The following is an itemized list of CP22 - UST FULL violotions that have riot been <br /> addressed far fast and easy mart#103 as of August 14, 2025, <br /> Open violations from May 22, 2025 inspection <br /> Vlolatlon M-20341016-Annular space of USTs are continuously monitored with an audible and visual <br /> alarm 6ystam(TCR 9d). <br /> 013SE iRVAT ION:During testing,the diesel annular sensor failed to activate both audible and visual alarms,indicating <br /> that the tank Is not currently being monitored.At the time of inspection,the annular sensor was found to be saturated <br /> wlih liquid,According to the techriician,the liquid appears to be water. A review of the alarm history showed no <br /> indication that an alarm had been triggered.The le&nician reported that he manually activated the annArsensor via <br /> the monitor pane!_As he is unable to remove the liquid from the annular space,the Sensor will remain achvated for <br /> ongoing monitoring. <br /> REGULATION GUIDANCP The interstitial space shall be monitored with a monitoring system connecfed to an eudibl2 <br /> and visual aluiin system. <br /> CORRECTIVE ACTION:Immediately contact a properly liconsed,trained,and certified contractor to replace the falled <br /> component with a functionel aorxiponent(LG 113-x listed,if applicable),and obtain a permit within one business day <br /> from the EHID,if needed. <br /> IN This violation was corrected [J This violation will he corrected by(date): <br /> ❑ Supporting documents Inctuded <br /> Describe actions taken or-vAll be taken to correct vinlatim: <br /> The diesel annular space was found to have water.The annular sensor was retested at the time of <br /> inspection on 5/22/2025 and passed the test.See page 5 of attached Monitoring Certification report. <br /> Violation 056,2060020-Spill buckets meet requirements, have been tested as required,and records kept <br /> for 36 nubs(TCR 9a). <br /> 0BSERVAT10N:The diesel direct-bury spill container failed when tested. <br /> REGULATION GUDANCE,All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill Until It is detected or cleaned up. <br /> CORRECTI EACTION: Immediately dierontinuc dcpo3ltion of petrcleurn into this tank until the component is repair <br /> or replaced by a properly licensed,trained,and certified contractor undar permit and inspection of the EHD, If the spill <br /> container can't tie replaced immediateiy, thAr,a is a pnssihility that the diesel UST system may be red tagged to <br /> prevent fuel inputs. <br /> */r/rk*F}F*A i•i-YYiiiilir#k►31k Y4f1i 1id*i <br /> 005tRVATION:Annual spill CmIalner WSting was previously perfor and on M"2023 and w83 oompletcd on June <br /> 2024, t months past due. <br /> REGIJLATION GUIDANCE'Th18 test is required upon complet-on of Installation and every 12 manth5 therealter. <br /> CCRRECTIVE ACTIDN-Take Ski necessary precautions to ensgre testing is perfurme0 in a timely manner_ <br /> Page 2 of 3 <br />