COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2026 1:29:46 PM
Creation date
5/9/2025 1:18:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231161
PE
2361 - UST FACILITY
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
07917039
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
8660 LOWER SACRAMENTO RD STOCKTON 95210
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
34 Outlook <br /> Re:Fast&Easy Mart#103 RTC form and supporting documents <br /> From Lopez,Maria[EHD]<melopez@sjgov.org> <br /> Date Mon 9/22/2025 11:12 AM <br /> To Diana Shinn<cersassistance@gmail.com> <br /> Cc Toya Chapagain<fastandeasytoya@gmail.com>;muhammad bilal<fasteasy101@gmail.com> <br /> Hello all, <br /> Violations: 3, 5, 9, 25, 69 are now CLOSED <br /> Violation # 50 remains OPEN <br /> Violation#50: Violation has not been addressed. This violation contains 2 observations that need to be addressed, only 1 of the 2 <br /> was addressed. Refer to attached screenshot of violation from report that needs to be addressed <br /> 50 CA Code of Regulations 2635,2637A,2665,2712 2060020-Spill buckets meet requirements,have been tested as <br /> required,and records kept for 36 mths(TCR 9a). <br /> OBSERVATION:The diesel direct-bury spill container failed when tested. <br /> REGULATION GUIDANCE:All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill until it is detected or cleaned up. <br /> CORRECTIVE ACTION:Immediately discontinue deposition of petroleum into this tank until the component is repaired <br /> or replaced by a properly licensed,trained,and certified contractor under permit and inspection of the EHD. If the spill <br /> oontainer can't be replaced immediately,there is a possibility that the diesel UST system may be red lagged to <br /> prevent fuel inputs. <br /> OBSERVATION:Annual spill container testing was previously performed on May 2023 and was completed on July <br /> 2024,1 months past due. <br /> REGULATION GUIDANCE:This test is required upon completion of installation and every 12 months thereafter. <br /> rn mns PRozauer scoot oenvmzs <br /> _Ho Rey_1-1 Page of cPzz.us>•FULL OR <br /> 1868 E.Hazelton Avenue l Stockton,California 95205 I T 2094BB-3420I F 209464-01361 www.slgov.orglEHD <br /> Violation#52: Note: violation says that it will be corrected annually in June, Overfill is required to be completed every 36 months <br /> NOT annually. <br /> REMINDER: please ensure test results are sent to ust@sjgov.org not inspectors <br /> Please reach out with any questions <br /> Maria E Lopez <br /> Environmental Health Specialist <br /> 1868 E.Hazelton Ave. <br /> Stockton,CA 95205-6232 <br /> Main Office:(209)468-3420 <br /> Cell:(209)616-3064 <br /> NOTE:I am out of the office every other Friday <br /> SAN JOAQUIN <br /> CC]UNTY <br /> Greatness grows here. <br /> From:Diana Shinn<cersassistance@gmail.com> <br /> Sent:Monday,August 25,2025 2:59 PM <br /> To:Lopez,Maria[EHD]<melopez@sjgov.org> <br /> Cc:Toya Chapagain<fastandeasytoya@gmail.com>;muhammad bilal<fasteasy101@gmail.com> <br /> Subject:Fast&Easy Mart#103 RTC form and supporting documents <br /> Good afternoon,Maria- <br /> Please find attached the RTC form along with the Annual Monitoring Certification Report,initial Spill Bucket Testing Report,and the Spill Bucket Testing Report for the retesting of <br /> the diesel spill bucket when the drain was replaced.Reportedly,these documents were provided to Inspector Saetern within the appropriate time frames after testing was <br /> completed. <br /> Let me know if you have any questions. <br />
The URL can be used to link to this page
Your browser does not support the video tag.