My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
2224
>
2300 - Underground Storage Tank Program
>
PR0232555
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2026 8:18:54 PM
Creation date
5/13/2025 1:09:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0232555
PE
2361 - UST FACILITY
FACILITY_ID
FA0003679
FACILITY_NAME
CALIFORNIA STOP*
STREET_NUMBER
2224
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16313007
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2224 MANTHEY RD STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) T1- 87 _ T2-91 T3-Diesel <br /> Are both vent and tank riser piping secondarily El Yes ❑ Yes El Yes ❑ Yes <br /> contained? ® No Z No ® No ❑ No <br /> OPE Model 61 SO 61 SO 61 SO <br /> What is the OPE response when activated? ® Shut off ® Shut off ® Shut off ❑ Shut off <br /> (Check all that apply.) Flow Flow Flow 1 Flow <br /> ❑Restricts ❑Restricts ❑Restricts ❑Restricts <br /> Flow Flow Flow Flow <br /> ❑ Audible ❑ Audible ❑ Audible ❑ Audible <br /> Alarm Alarm Alarm Alarm <br /> ❑ Visual ❑ Visual ❑ Visual 1 ❑ Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping that ❑ Yes* ❑ Yes* ❑ Yes* ❑ Yes* <br /> may interfere with the OPE operation? ® No 1 ® No ® No ❑ No <br /> At what level in the tank is the OPE set to 1 <br /> activate? (Inches from bottom of tank) 83" 33" 72" <br /> What is the percent capacity of the tank at <br /> which the OPE activates? 95% 95% 84% <br /> Is the OPE in proper operating condition to ® Yes El Yes ® Yes ❑ Yes <br /> respond when the stored substance reaches the ❑ No El No El No El No <br /> designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results ®Pass KPass ®Pass El Pass <br /> ❑Fail ❑Fail ❑Fail ❑Fail <br /> 8. COMMENTS <br /> Describe all results marked "Fail'and each proposed remedy. <br /> * Mark here if: <br /> ❑ Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />