My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2026 9:09:27 PM
Creation date
5/14/2025 9:02:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231074
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4627 DA VINCI DR STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name:Facility Phone:Date: <br />7-ELEVEN INC #20632 (209) 952-3543 December 16, 2025 <br />CERS ID:Facility Address: <br />4627 DA VINCI DR, STOCKTON, CA 95207 10165883 <br />Phone: <br />(949) 761-2907 <br />Title: <br />Manager <br />Inspection Contact: <br />Rocky Arttu <br />Inspection Type: <br />Routine <br />Program: <br />2351 - UST FACILITY - 2481 COMPLIANT <br />Consent Given By: <br />Rocky Arttu, Manager <br />Consent For: <br /> Inspection Photos Samples <br />Service Technician Onsite:Exp. Date:Designated Operator:Exp. Date: <br />3/26/2027Fernando Solis1/5/2026Benjamin Baunach <br />Service Technician Manufacturer's Training: <br />Veeder-Root, 12/13/2026; OPW, 7/28/2026; VMI, 4/23/2027 <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations EHD = Environmental Health Department <br />OUT = Violation R = Repeat Violation COS = Corrected on site during inspection <br />1 HSC 25284; CCR 2711 <br />(d) <br />2030021 - Facility has a valid Permit to Operate from the CUPA OUT R COS <br />2 CCR 2711 2010010 - Complete and accurate UST Operating Permit Application has been <br />submitted. <br /> OUT R COS <br />3 CCR 2632(d)(1), 2634(d) 2010013 - Facility has submitted a complete and accurate UST Monitoring Plan. OUT R COS <br />4 CCR 2632(d)(2), 2634(e) 2010014 - Facility has submitted a complete and accurate UST Response Plan. OUT R COS <br />5 CCR 2632(d), 2641(h) 2030041 - A current facility plot plan is maintained and has been submitted OUT R COS <br />6 HSC 25299(a)(8), 25299 <br />(b)(7) <br />2010006 - Owner/Operator has not made false statements, certifications, or <br />representations on documents <br /> OUT R COS <br />7 CCR 2715(a)(1)(B), 2715 <br />(a)(3) <br />2010003 - Owner/Operator submitted DO form and/or informed the CUPA of any <br />change(s) within 30 days (TCR 10) <br /> OUT R COS <br />8 CCR 2715(a)(1)(A), 2715 <br />(a)(2) <br />2010016 - "Underground Storage Tank Statement of Understanding and <br />Compliance Form" submitted (TCR 10) <br /> OUT R COS <br />9 CCR 2638, 2641(j), 2715 <br />(f) <br />2030002 - Leak detection equipment tested by qualified service technician every <br />12 months (TCR 9d) <br /> OUT R COS <br />10 CCR 2638(c), 2638(d) 2030074 - Annual Monitoring System Certification Form to the CUPA within 30 <br />days of completion of the test <br /> OUT R COS <br />11 CCR 2637(a-d), 2712(b) <br />(1)(F) <br />2030048 - Sec containment testing conducted per requirements & records kept for <br />36 mths (TCR 9d) <br /> OUT R COS <br />12 CCR 2637(e), 2637(f) 2010009 - Secondary containment test results submitted to the CUPA within 30 <br />days after the test. <br /> OUT R COS <br />13 CCR 2637.1(d), 2637.1 <br />(e) <br />2010017 - Spill bucket testing results submitted to the UPA within 30 days of testing OUT R COS <br />14 CCR 2637.2(d&e), 2665 <br />(a&b) <br />2010018 - Overfill prevention equipment inspection report form submitted to the <br />UPA within 30 days <br /> OUT R COS <br />15 CCR 2636(f)(3), 2643(c) <br />(3) <br />2030042 - Line integrity test completed on DW press piping every 12 mths if no fail <br />safe / + shutdown (TCR 9d) <br /> OUT R COS <br />16 CCR 2643(d), 2661(f) 2030050 - 0.1 gph piping test conducted on SW suction systems every 36 mths <br />and after piping repair (TCR 9d) <br /> OUT R COS <br />17 CCR 2643(e), 2661(f)2030051 - 0.1 gph piping test conducted on SW gravity systems every 24 mths and <br />after piping repair (TCR 9d) <br /> OUT R COS <br />18 CCR 2663, 2712(b)(6) 2030029 - Tank lining inspected w/in 10 years of lining, every 5 years after, cert <br />submitted to CUPA (TCR 9c) <br /> OUT R COS <br />19 CCR 2644.1(a)(5) 2010005 - ELD testing results sent to the board and the CUPA within 60 days of <br />completion of the test <br /> OUT R COS <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 1 of 6EHD - CUPA Inspection Report IS03 <br />CP22 - UST FULL <br />12/16/2025FA0002541 PR0231074 4589456