My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
505
>
2300 - Underground Storage Tank Program
>
PR0231442
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2026 8:32:47 PM
Creation date
5/27/2025 11:05:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231442
PE
2361 - UST FACILITY
FACILITY_ID
FA0006441
FACILITY_NAME
QUIK STOP MARKET #124
STREET_NUMBER
505
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21726021
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
505 N MAIN ST MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Monitoring System Certification Form <br /> 8. IN-TANK GAUGING TESTING <br /> F Check this box if tank gauging is used only for inventory control. <br /> ® Check this box if NO tank gauging equipment is installed. Yes No NA <br /> Do not complete this section if either box is checked. <br /> All wiring has been: 1) visually inspected for kinks, breaks and proper entry and <br /> termination; and 2 tested for ground faults? <br /> Were all in-tank gauging probes visually inspected for damage and residue buildup 0 <br /> to ensure that floats move freely, functionally tested, and confirmed operational? <br /> Was accuracy of system's product level readings tested? 0 <br /> Was accuracy of system's water level readings tested? El El 11 <br /> Were all probes reinstalled properly? El 17 <br /> Were all items on the equipment manufacturer's maintenance checklist completed? El I ® I 0 <br /> Probe ID Probe Model Tanks Monitored Pass Fail <br /> 17 r] <br /> © ❑] <br /> 0 <br /> IF] 17 <br /> © El <br /> © 0 <br /> 9. COMMENTS <br /> Describe all answers marked "No"or "Fail"and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> During testing of 87-2 auxiliary MLD, leak detection tester box broke internally and started <br /> seeping fuel from its side. Will need to return at a later date to complete MLD leak detection <br /> testing on the 87-2 auxiliary and 91 product lines. <br /> Page 5 of 6 <br />