My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2026 12:51:14 PM
Creation date
6/3/2025 1:33:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231127
PE
2361 - UST FACILITY
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1612 W HAMMER LN STOCKTON 95209
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> PARKWOODS GAS & FOOD 1(209) 951-9707 MaV 30 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 3 CA Code of Regulations 2632(d)(1), 2634(d) 2010013- Facility has submitted a complete and accurate UST <br /> Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br /> -The monitoring plan states that the floats and chains were located in UDC's 5/6 and 7/8. The floats and chains were <br /> observed to be located in UDC's 1/2 and 3/4. <br /> -The monitoring plan states that the 208 sensors were located in UDC's 1/2 and 3/4. The 208 sensors were observed to <br /> be located in UDC's 5/6 and 7/8. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br /> (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a Repeat (Class 2)Violation. <br /> 7 CA Code of Regulations 2715(a)(1)(B), 2715(a)(3) 2010003- Owner/Operator submitted DO form and/or informed the <br /> CUPA of any change(s)within 30 days (TCR 10) <br /> OBSERVATION: A new designated operator, David Winkler, began conducting inspections on 3/5/25 and notification <br /> was not provided to the EHD within 30 days of the change. <br /> REGULATION GUIDANCE: The owner or operator shall submit a "Designated Underground Storage Tank Operator <br /> Identification Form" no later than 30 days after any change in the designated UST operator(s). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is a Repeat (Class 2)Violation. <br /> 53 CA Health and Safety Code 25292.2; CCR 2711(a)(11) 2010007- Submitted/maintained current Cert of Financial <br /> Responsibility/mech of financial assurance (TCR 11) <br /> OBSERVATION: Current financial responsibility documents (dated 5/7/25)were not found on site. <br /> REGULATION GUIDANCE: A copy of current financial responsibility documents are required to be maintained on site. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br /> copy on site. <br /> This is a Repeat (Class 2)Violation. <br /> 56 CA Code of Regulations 2716(a-e) 2030013 - DO inspections completed at least every 30 days and meet all <br /> requirements (TCR 12) <br /> OBSERVATION: Designated operator reports were not signed within the required time frame. <br /> -The 7/9/24, 8/1/24, and 8/28/24 designated operator reports were not signed by the owner/operator. <br /> REGULATORY GUIDANCE: Within 48 hours of the completion of the designated UST operator visual inspection, the <br /> designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 hours of <br /> being provided a signed copy of the report, the owner or operator shall provide a description of each corrective action <br /> taken or to be taken and shall sign and date the report, acknowledging the identified compliance issues. <br /> CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the required <br /> time frame in the future. <br /> This is a Repeat (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS01 Page 5 of 6 FA0003611 PR0231127 4513852 5/30/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.