My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2026 8:36:44 PM
Creation date
6/12/2025 4:48:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0540345
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
WAY
City
Tracy
Zip
95377
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
5655 Hood WAY Tracy 95377
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2006 <br />Spill Bucket Testing Report Form <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />1. FACILITY INFORMATION <br />Facility Name: Fed Ex Ground Date of Testing: 6/30/2025 <br />Facility Address: 5655 Hood Way, Tracy, CA 95377 <br />Facility Contact: Phone: - <br />Date Local Agency Was Notified of Testing: 6/30/2025 <br />Name of Local Agency Inspector (if present during testing): Unkown <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: TANKNOLOGY INC. <br />Technician Conducting Test: Jesus Saldivar <br />Credentialsl: F CSLB Contractor F TCC Service Tech. F SWRCB Tank Tester F Other (Specify) <br />License Number(s): <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used By: F Hydrostatic F40- Vacuum r— Other <br />Test Equipment Used: VACUUM TEST Equipment Resolution: 0.1 gph <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />Spill Box # Tank T-1 Diesel <br />'Fill 1 -Direct -Grade level <br />in containment sump <br />Spill Box # Tank T-2 Diesel <br />-Fill 1 -Direct -Grade level <br />in containment sump <br />Spill Box # Tank T-3 <br />Biodiesel - Fill 1 - Direct - <br />Grade level in containment <br />sump <br />Spill Box # <br />Bucket Installation Type: <br />C' Direct Bury <br />ro Contained in Sump <br />r Direct Bury <br />10 Contained in Sump <br />r Direct Bury <br />1* Contained in Sump <br />r Direct Bury <br />r Contained in Sump <br />Bucket Diameter: <br />12.00 <br />12.00 <br />12.00 <br />Bucket Depth: <br />16.00 <br />16.00 <br />16.00 <br />Wait time between applying <br />vacuum/water and start of test <br />1 min <br />1 min <br />1 min <br />min <br />Test Start Time (Tl): <br />09:00:00 <br />09:02:00 <br />09:04:00 <br />Initial Reading (Rl): <br />30.00 in. H2O <br />30.00 in. H2O <br />30.00 in. H2O <br />Test End Time(TF): <br />09:01:00 <br />09:03:00 <br />09:05:00 <br />Final Reading (RF): <br />28.00 in. H2O <br />28.00 in. H2O <br />30.00 in. H2O <br />Test Duration(TF—TI): <br />1 min <br />1 min <br />1 min <br />Change in Reading (RF—Rl) : <br />-2.00 in. H2O <br />-2.00 in. H2O <br />0.00 in. H2O <br />Pass/Fail Threshold or Criteria: <br />+/-4.00 <br />+/-4.00 <br />+/-4.00 <br />+/- <br />Test Result: <br />Pass <br />Pass <br />Pass <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />You have to take Fill sumo lids off to be able to null vacuum. Or you have to test with H2O leak test. <br />CERTIFICATION OF TECB NICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: <br />Date: 6/30/2025 <br />'State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. <br />WO: 2375942 <br />
The URL can be used to link to this page
Your browser does not support the video tag.