Laserfiche WebLink
SANsJOAQUIN AMENDED Environmental Health Department <br /> COUNTY 7/30/2025 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> UNITED #5447 11469 E HAMMER LN, STOCKTON TJuly 28, 2025 <br /> 69 CA Code of Regulations 2712(i) 2030033 -A current UST monitoring plan has been submitted and is readily accessible <br /> at the facility <br /> OBSERVATION: An approved copy of the monitoring plans were not available for inspection. <br /> -The monitoring plan found on site was outdated, it included the following tank grades information: Premium, Diesel, <br /> Midgrade and Regular Unleaded. Currently, there is no "Midgrade", instead there are 2 "Regular Unleaded". <br /> REGULATION GUIDANCE: A copy of these plans shall be accessible on site at all times. <br /> CORRECTIVE ACTION: Immediately locate the current monitoring plans and retain a copy on site. <br /> This is a Repeat(Class 2)Violation. <br /> 72 CA Code of Regulations 2712 2030039 - Compliance with all operating permit requirements <br /> OBSERVATION: The facility is not in compliance with the written conditions of the operating permit. <br /> - The Permit Conditions states that written monitoring and maintenance records shall be maintained on-site for a period <br /> of at least 3 years. The following records are missing: <br /> -Spill Container Test Results completed on 7/11/2024 <br /> - Monitoring System Certification Test Results completed on 7/11/2024 <br /> -Overfill Prevention Equipment Test Results completed on 7/11/2024 <br /> REGULATION GUIDANCE: The owner and operator of underground storage tank(UST) systems shall comply with all <br /> requirements of the permit issued for the operation of the UST system. <br /> CORRECTIVE ACTION: Immediately take all necessary actions to bring these UST systems into compliance. Locate the <br /> missing records and provide a statement to EHD. <br /> This is a (Class 2)Violation. <br /> 77 CA Code of Regulations 2712(f) 2030073 - Facility has corrected cited violations within 30 days of receiving report <br /> OBSERVATION: An inspection was last done on 7/11/2025 and an inspection report was issued identifying information <br /> to be submitted to bring this site into compliance. This information was required to be submitted by 8/10/2024. This <br /> information was received on 8/19/2024, 9 days late. <br /> REGULATION GUIDANCE: An operator that receives an inspection report shall have 30 days to implement the <br /> corrections specified in the inspection report and comply with permit conditions. The corrective action shall include all of <br /> the recommendations made in the report. The operator shall submit a written response that includes a statement <br /> documenting corrective actions taken or proposing corrective actions which will be taken. <br /> CORRECTIVE ACTION: Ensure that a written response documenting corrective actions taken or proposed is submitted <br /> and all corrections implemented within 30 days of receiving an inspection report. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 6 of 7 FA0001570 PR0231126 4529628 7/30/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />