My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
983
>
2300 - Underground Storage Tank Program
>
PR0231691
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2026 12:05:08 PM
Creation date
6/25/2025 4:55:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231691
PE
2361 - UST FACILITY
FACILITY_ID
FA0003593
FACILITY_NAME
FLYER ENERGY #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
BLVD
City
Manteca
Zip
95336
APN
22115006
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
983 Moffat BLVD Manteca 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQ U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FLYER ENERGY#487 983 Moffat BLVD, Manteca July 28, 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 45 CA Code of Regulations 2636(f)(2) 2030025- LLD on DW press piping monitors hrly, detects a 3.0 gph leak, and <br /> restricts/shuts off flow (TCR 9d) <br /> OBSERVATION: The 91 VMI line leak detector failed to detect a leak when tested. <br /> REGULATION GUIDANCE: All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. <br /> CORRECTIVE ACTION: Corrected on-site. The service technician adjusted the leak detector, retested it, and it passed. <br /> This is a Repeat(Class 2)Violation. <br /> 53 CA Health and Safety Code 25292.2; CCR 2711(a)(11) 2010007 - Submitted/maintained current Cert of Financial <br /> Responsibility/mech of financial assurance (TCR 11) <br /> OBSERVATION: Financial responsibility documents have not been submitted to the EHD. The most recent UST Letter <br /> from Chief Financial Officer document in CERS is dated 05/31/2024. <br /> REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, and upload the required documents. <br /> OBSERVATION: Current financial responsibility documents were not found on site. The financial responsibility document <br /> observed on-site was dated 12/29/2023 and the Letter from Chief Financial Officer document observed on-site was dated <br /> 05/31/2024. <br /> REGULATION GUIDANCE: A copy of current financial responsibility documents are required to be maintained on site. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br /> copy on site. <br /> This is a Repeat(Class 2)Violation. <br /> 56 CA Code of Regulations 2716(a-e) 2030013 - DO inspections completed at least every 30 days and meet all <br /> requirements (TCR 12) <br /> OBSERVATION: Designated operator reports were not signed within the required time frame. <br /> -The 1/8 designated operator report was signed by the owner/operator on 1/16. <br /> -The 2/5 designated operator report was signed by the owner/operator on 2/11. <br /> -The 5/2 designated operator report was signed by the owner/operator on 5/7. <br /> -The 5/2 designated operator report was signed by the owner/operator on 5/7. <br /> -The 5/30 and 6/27 designated operator reports were not signed. <br /> REGULATORY GUIDANCE: Within 48 hours of the completion of the designated UST operator visual inspection, the <br /> designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 hours of <br /> being provided a signed copy of the report, the owner or operator shall provide a description of each corrective action <br /> taken or to be taken and shall sign and date the report, acknowledging the identified compliance issues. <br /> CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the required <br /> time frame in the future. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 5 of 6 FA0003593 PR0231691 4529656 7/28/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.