General Notes - Demolition _ _
<br /> sign
<br /> 1. THIS AND ANY OTHER DEMOLITION DRAWINGS ARE NOT INTENDED TO BE ALL INCLUSIVE AND 713 washington street
<br /> Cl
<br /> MAY NOT DEFINE THE SCOPE OF ALL DEMOLITION WORK REQUIRED FOR THIS PROJECT. _ _ texas 80
<br /> 28
<br /> DEMOLITION DRAWINGS ARE SHOWN ONLY TO AID THE CONTRACTOR IN PREPARING FOR THE 830.890.8808/
<br /> BID AND PERFORMING THE WORK. CONTRACTOR SHALL EXAMINE ALL CONSTRUCTION
<br /> DOCUMENTS AND VISIT THE SITE DURING THE BIDDING PROCESS AS REQUIRED TO DETERMINE t sacramento,ca.916.980.9165
<br /> THE FULL SCOPE OF THE WORK, ALL ITEMS ELECTRICAL, HVAC, PLUMBING, STRUCTURAL , 1 10 11 jmwellsdesign@gmail.com/
<br /> ARCHITECTURAL, FINISH ETC. THAT ARE NOT REQUIRED TO REMAIN, SHALL BE PART OF THE 6 - 0, 1/ 11
<br /> jackmwells@outlook.com
<br /> DEMOLITION WORK REQUIRED TO CARRY OUT WORK AS SHOWN IN THE CONSTRUCTION �*�_� (�) SIDEWALK COPY RIGHT 2 0 24
<br /> DOCUMENTS. NOT PUBLISHED.ALL RIGHTS RESERVED BY DESIGNER. DRAWINGS
<br /> AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL
<br /> REMAIN THE PROPERTY OF THE DESIGNER.THEY SHALL NOT BE USED
<br /> ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY
<br /> GOIUmn GOVFir.7___________ _________ AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO
<br /> 2. GENERAL CONTRACTOR TO REMOVE EXISTING CONSTRUCTION TO ACHIEVE A CLEAN SPACE THE DESIGNER.CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND
<br /> READY FOR CONSTRUCTION. CORRELATION DIMENSIONS AT THE JOB SITE,THE DESIGNER WILL NOT
<br /> L 1� NEW L Y V I VJ I�ll I V BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS,
<br /> TECHNIQUES, SEQUENCES OR FOR SAFETY PRECAUTIONS AND
<br /> LINE OF EXISTING ROOD TO Thl5 Store. front appears to PROGRAMS IN CONNECTION WITH THE PROJECT.
<br /> 3. VISIT SITE, EXAMINE EXISTING CONDITIONS AND CONDITIONS SURROUNDING SITE, DETERMINE bq c/o° From main wall of
<br /> REQUIREMENTS UNDER WHICH WORK SHALL BE PERFORMED. i REMAIN boilding (google earth) ... EXISTING
<br /> (E) GONGR)=TE CURB TO ENTRANCE Company,
<br /> 4. PROTECT AND MAINTAIN ALL ELEMENTS WHICH ARE TO REMAIN OR WHICH ARE TO REMAIN
<br /> LLC
<br /> UNTIL NEW PERMANENT INSTALLATIONS ARE COMPLETE. REMAIN Daryl Jordan,P.E.
<br /> PO Box 467
<br /> -� (E) LANDSCAPE BED TO Mount Hermon,CA 95941
<br /> 5. TAKE PRECAUTIONS NECESSARY TO PROTECT ADJOINING SPAC ROM EXCESSIVE DUST AND
<br /> REMAIN I I I I I (209) 485-8620
<br /> DEBRIS, AND ASSUME FULL RESPONSIBILITY FRQM aNMAGES RESULTN.G FROM NEGLIGENCE OF
<br /> THESE ITEMS. L1 —----____— ------ OQ�oA1SJ0oN��c�` �•
<br /> �� P� Req •
<br /> b. CLEAN AND PROTECT CONSTRUCTION IN PROGRESS AND A JOINT G MATERIALS IN PLACE. I i
<br /> PLEASE Ar_,fLRAtLT DIMENSION
<br /> 7. APPLY PROTECTIVE COVERING WHERE REQL IRED TOE SURE DROTECTION FROM DAMAGE i STOREFRONT
<br /> OR DETERIORATION. I ALSO RL-EASE PRO/IDE
<br /> OOMPREH' NSI /E DIMENSIONS OF= ` CIVI\.
<br /> 8. IF UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL EWE ENTS CONFLICT WITH I THE DININRATIO SO-THAT A ) ) ) FOF \FO`s
<br /> CA1-
<br /> THE INTENDED FUNCTION OR DESIGN, INVESTIG TE AND MEASURE N01H NATURE AND EXTENT I i GOMPLET I EMOLITION PLAN... Iv t v t Iv
<br /> OF THE CONFLICT. SUBMIT REPORT TO THE DESIGN PROFESSIONAL IN WRITTEN DETAIL. I LI MAT LSE
<br /> REARRANGE SCHEDULE AS NECESSARY TOCONTINUE O ERAL JOB PROGRESS. Ilid lid I lid
<br /> date of issue/revisions:
<br /> 9. REMOVE FROM BUILDING SITE ALL DEBRIS, RUBBISH AND MAT RI W W W W
<br /> I I I I I I I
<br /> DEMOLITION. TRANSPORT AND LEGALLY DISPOSE OF OFF-SITE. I no. date description
<br /> I I I I I I I
<br /> I I I i I I I I
<br /> 10. REMOVE AND DISPOSE OF ALL ABANDONED EQUIPMENT IN SP C .
<br /> I I I I I I
<br /> EXTERIOR DIMENSIONS SHOWN ARE TO FACE TO EDGE OF SLAB, ALLtOTHER DIMENSIONS ARE TO
<br /> FACE OF FINISH UNLESS OTHERWISE NOTED. = I 1 �-- I I I I
<br /> -------------------------- ------------------------------------------------------ -
<br /> GENERAL CONTRACTOR TO DISPOSE OF ALL W STE DURING DE O ORDANCE EXISTINO DININ PATIO ATELT DIMENSIONEXISTINO DININC ROOM
<br /> STOREFIl�-I3 IS w NEN �\
<br /> POS
<br /> WITH ALL APPLICABLE JURISDICTIONS, CODES AND RDIN N6� . I TO BE DEMOLISHED PROPOSES/'BUILDING WILL TIE IN "NO WORK AT INTERIOR OF EXISTING
<br /> Ll
<br /> /���� RESTAURANT"
<br /> GENERAL CONTRACTOR TO FIELD LOCATED A DPACTT ATE IF, If / LLS TO BE DEMOLISHED ,
<br /> ALL EXISTING"HOT" ELECTRICAL WIRING PRIOR Oq� MOLI ION.
<br /> u
<br /> CONTRACTOR TO VERIFY ALL DIMENSIONS ON 31TEANDNOTIFY DESIG,,4 PROFESSIONALS OF
<br /> ANY DISCREPANCIES IMMEDIATELY, PRIOR TO RO EEDIN . III
<br /> ALL EXISTING WALL FINISHES THROUGHOUT THE SAID WOR (UNF 10HALL BE REMOVED.
<br /> III 1 1
<br /> I
<br /> REFER TO OWNER FOR COORDINATION OF ALL PROPOSED MECHANICAL, ELECTRICAL AND
<br /> PLUMBING EQUIPMENT.
<br /> I
<br /> CONTRACTOR SHALL PERFORM AN THOROUGH INVESTIGATION LOOR, WALL
<br /> AND/OR ROOF FRAMING SYSTEMS WITH-IN THE ARE OF FIRE DAMAGED AREA AND REPLACE I„ SERVICE
<br /> O
<br /> ANY DAMAGED STRUCTURAL SYSTEMS. �# 4 ���� 2
<br /> III `
<br /> Demolition 1 t -
<br /> O
<br /> Notes:
<br /> = O
<br /> III I •- O
<br /> 1 Completely remove existing outdoor dining slab, canop ink ding all associated parts,
<br /> cover, columns, fencing, etc. Saw-cut adjacent pav mens at building line of proposed ❑ OIii 4 i L■
<br /> improvements. Note: DO NOT UNDERMINE EXISTING IFOOTIGS ND OR BEAMS. Provide
<br /> pictures/ documentation of existing building co ditio s to design professionals of existing
<br /> building conditions encountered during pro sses L
<br /> -
<br /> 2 Completely remove door, door fram®�) and are and all related accessories. Salvage if
<br /> directed by owner.
<br /> I I
<br /> 3 Remove existing stucco soffit at line of interic r pf prOPOSE d dini ig room addition.
<br /> 0
<br /> 4 Remove existing exterior lighting fixtures at soffit/ fascia wesi end of existing building,
<br /> back to source. C cc
<br /> 5 Remove existing rock feature,west end of building. O
<br /> b cc
<br /> V
<br /> tv O
<br /> - - = NJ a+
<br /> •- LM O
<br /> III
<br /> I Q Q
<br /> 3 , I
<br /> vitZ
<br /> I I
<br /> _� I
<br /> ) r ®
<br /> � I I
<br /> O ,
<br /> 0 I I
<br /> CD
<br /> 3 I I
<br /> I I
<br /> � I I
<br /> C14_
<br /> Z / I
<br /> C6'- 11 Z U
<br /> Q
<br /> Z O 4
<br /> EA I--
<br /> M
<br /> m }
<br /> I I W �
<br /> N I I
<br /> ry
<br /> ry 0 WO U
<br /> O -
<br /> (E) GOdLER "' e
<br /> �, - --------------------------- -------------------- ---------- ------- ------- ---------------------------- W U ._�
<br /> ---I I
<br /> - I �O ° U o 0
<br /> General Notes " �F = = 0W)
<br /> w ----------------------- --- n l
<br /> I 5 W a Ill
<br /> CD a ii Wo Wi�1 � 10
<br /> � M00
<br /> 1. WRITTEN DIMENSIONS SHALL TAKE RE EDENCE OVER SCALED DIMENSIONS, - "' 2 as00
<br /> `"-) "DRAWINGS ARE NOT TO BE SCALED".
<br /> N ---------------------F6 --------------- --_ -------- -------
<br /> _ _______ _L_-----�---1 _ -------____ _ L a O O
<br /> - IIII -
<br /> T Ilp II n I I II II I I I O
<br /> 2. DIMENSIONS ARE TO FACE OF FRAMING JNLESS OTHERWISE NOTED. " 11
<br /> sheet contents
<br /> 0 3. ALL EXTERIOR SIGNAGE SHALL BE BY OWNER, AND SHALL REQUIRE A SEPARATE PERMIT. '1 ___________________��_____ _______________��___ _ "--------- ____________ =L=_==� =J = _________ "- Existing Conditions/
<br /> II II II __FF_________ _yt II ---
<br /> 0 4. PROVIDE APPROVED STREET ADDRESS/ SUITE NUMBER POSITIONED SUCH AS TO BE Demolition
<br /> U PLAINLY VISIBLE AND LEGIBLE FROM THE STREET. NUMBERS SHALL CONTRAST WITH THEIR O
<br /> BACKGROUND WITH A MINIMUM 6" HIGH CHARACTER 3/4" STROKE RECOMMENDED. UFC
<br /> 011 901.4.4.
<br /> 5 A. ARMENIMUMUI OF ONE 2A:1 OBC FIRE EXTINGUISHER SHALL BE PROVIDE PER "SPACE". NORTH 10,111%° 61 3q 11 s'-10/211 V 11 3'-103/q" I%" 3'-�2" 4 3_II 4 20'_011 project no
<br /> Z PLAN
<br /> -lo/ " /" 5,_3„ - 241 Ol
<br /> Ce TRAVEL DISTANCE TO REACH THE EXTINGUISHER SHALL NOT EXCEED 75 FEET AND drawn by
<br /> Ce MOUNTING HEIGHT SHALL NET EXCEED 48 INCHES ABOVE FINISH FLOOR. CFC SEC 1002. jm
<br /> J p� B. ALL FIRE EXTINGUISHERS SHALL BE MOUNTED IN EASILY ACCESSIBLE LOCATIONS, FREE checked by
<br /> N FROM OBSTRUCTIONS. SIGNS MAY BE REQUIRED WHEN EXTINGUISHER IS NOT READILY = Existing Conditions/ Demolition Plan West Elevation - Demolition project architect JMW/DJ
<br /> VISIBLE. UFC STD 10-1.
<br /> C� 00
<br /> 3 02
<br /> 6. INTERNALLY OR EXTERNALLY ILLUMINATED"EXIT"SIGNS SHALL BE INSTALLED AT EACH EXIT 1/4''= 1'-0 3/16"= 1'-0
<br /> AND WHERE OTHERWISE NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS. APPROXIMATE 06242024
<br /> Q 3 EXCEPTION - MAIN EXTERIOR DOORS THAT OBVIOUSLY ARE CLEARLY INDENTIFIABLE AS EXISTS plot date
<br /> / NORTH
<br /> WHEN APPROVED BY THE BUILDING OFFICIAL. UFC 1212.1 LA sheet number
<br /> } 0
<br /> 0 7. FIRE SPRINKLER SYSTEM PLANS AND SPECIFICATIONS SHALL BE SUBMITTED SEPARATELY
<br /> E TO THE FIRE DEPARTMENT FOR APPROVAL. INSTALLATION SHALL BE IN ACCORDANCE WITHAl
<br /> 0 NFPA 13, 2022. EXISTING SYSTEM SHALL BE ADJUSTED BY LICENSED CONTRACTOR TO MEET •
<br /> C NEW CEILINGS HEIGHT OF THIS PROJECT.