My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2026 8:35:14 PM
Creation date
7/10/2025 9:08:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231425
PE
2361 - UST FACILITY
FACILITY_ID
FA0003838
FACILITY_NAME
FRONTIER CALIFORNIA INC. MANTECA CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21721070
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
430 W CENTER ST MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANsJOAQUIN AMENDED Environmental Health Department <br /> COUNTY 8/6/2025 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: TAuqust <br /> ate: <br /> Frontier California Inc.: Manteca CO 1430 W Center ST, Manteca 05, 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 24 CA Code of Regulations 2632(c), 2634(d), 2636(f) 2030003 - Leak detection system maintains continuous monitoring <br /> that activates an audible and visual alarm <br /> OBSERVATION: The monitoring panel malfunctioned and is no longer operational in its current state. <br /> REGULATION GUIDANCE: All monitoring equipment shall be maintained to activate an audible and visual alarm or stop <br /> the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: Correct immediately by having a properly licensed, trained, and certified contractor replace the <br /> failed component with a functional component(LG 113-x listed, if applicable), and obtain a permit within one business <br /> day from the EHD, if needed. <br /> If the failed component can't be replaced immediately, there is a possibility that the diesel UST system may be red <br /> tagged to prevent fuel inputs. <br /> This is a (Class 2)Violation. <br /> 25 CA Code of Regulations 2631(g), 2632(c)(2) 2030016 -Annular space of USTs are continuously monitored with an <br /> audible and visual alarm system (TCR 9d) <br /> OBSERVATION: The diesel annular sensor failed to activate an audible and visual alarm when tested and, therefore, the <br /> tank is not monitored. <br /> REGULATION GUIDANCE: The interstitial space shall be monitored with a monitoring system connected to an audible <br /> and visual alarm system. <br /> CORRECTIVE ACTION: Corrected on-site. The sensor was replaced and retested during the inspection. <br /> OBSERVATION: The diesel annular sensor failed to activate an audible and visual alarm when tested and, therefore, the <br /> tank is not monitored. This is due to monitoring panel malfunction. <br /> REGULATION GUIDANCE: The interstitial space shall be monitored with a monitoring system connected to an audible <br /> and visual alarm system. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to replace the failed <br /> component with a functional component(LG 113-x listed, if applicable), and obtain a permit within one business day from <br /> the EHD, if needed. <br /> This is a Repeat(Class 2)Violation. <br /> 36 CA Health and Safety Code 25290.1(d) 2060023 - System has a mon system that can detect entry of haz sub <br /> liquid/vapor, or water into sec contain <br /> OBSERVATION: The diesel piping sump and diesel fill sump sensor failed to activate an audible and visual alarm when <br /> tested to ensure continuous monitoring of the tank system. <br /> REGULATION GUIDANCE: All monitoring equipment shall be maintained to activate an audible and visual alarm or stop <br /> the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: Correct immediately by having a properly licensed, trained, and certified contractor replace the <br /> failed component with a functional component(LG 113-x listed, if applicable), and obtain a permit within one business <br /> day from the EHD, if needed. <br /> If the failed component can't be replaced immediately, there is a possibility that the diesel UST system may be red <br /> tagged to prevent fuel inputs. <br /> This is a (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 5 of 7 FA0003838 PR0231425 4533111 8/6/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.