My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2758
>
2300 - Underground Storage Tank Program
>
PR0541416
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2026 9:28:44 PM
Creation date
8/20/2025 11:39:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0541416
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0023733
FACILITY_NAME
SUNWEST CHEVRON
STREET_NUMBER
2758
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
Lodi
Zip
95242
APN
16646031
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2758 W Kettleman LN Lodi 95242
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN AMENDED Environmental Health Department <br />COUNTY— 10/22/2025 <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />SUNWEST CHEVRON <br />2758 W KETTLEMAN LN, LODI <br />October 16, 2025 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />28 <br />CA Code of Regulations 2638(a), 26410) 2030043 - Leak detection equipment properly installed, calibrated, operated, <br />and maintained (TCR 9d) <br />OBSERVATION: The brine levels in the UDCs, STP sumps and Fill sumps were not adequate to ensure proper <br />monitoring. Within the UDCs many of the atmospheric manometers did not have any brine. Per the service tech, the STP <br />sumps and Fill sumps did not have enough brine. The service tech did not have brine on hand, therefore he was unable <br />to correct the violation on site. <br />REGULATION GUIDANCE: All monitoring equipment shall be installed, calibrated, operated, and maintained in <br />accordance with manufacturer's instructions, and certified for operability, proper operating condition, and proper <br />calibration. Immediately contact a properly licensed and certified contractor to ensure all sumps contain adequate levels <br />of brine per manufacturer's instructions. <br />CORRECTIVE ACTION: Ensure that all leak detection equipment is properly programmed and maintained at all times <br />and provide proof to EHD. <br />This is a (Class 2) Violation. <br />56 <br />CA Code of Regulations 2716(a -e) 2030013 - DO inspections completed at least every 30 days and meet all <br />requirements (TCR 12) <br />OBSERVATION: The only Designated Operator Visual Inspection Report available for review was from 10/31/2024, 350 <br />days ago. <br />REGULATION GUIDANCE: The designated operator visual inspections shall be conducted within 30 days or less of the <br />previous inspection. <br />CORRECTIVE ACTION: Ensure that all designated operator inspections are performed within the required time frames. <br />This is a Repeat (Class 2) Violation. <br />72 <br />CA Code of Regulations 2712 2030039 - Compliance with all operating permit requirements <br />OBSERVATION: The s17: Regular Product Vacuum Sensor was replaced on 9/23/2025 and a permit was not obtained <br />from the EHD. <br />- A sensor replacement that is like for like requires a "UST Retrofit - No Fee Permit", where certain conditions need to be <br />met. For this replacement that was done on 9/23/2025, the conditions were not met. <br />REGULATION GUIDANCE: Emergency repairs relating to UST system monitoring and release detection may be <br />performed by a properly licensed, trained, and certified contractor pursuant to the EHD's policy and a permit obtained <br />within one business day from the EHD. All other repairs must have a permit submitted to and approved by the EHD prior <br />to beginning work. <br />CORRECTIVE ACTION: Immediately obtain a permit from the EHD for the replaced s17 sensor. A "Failure to Obtain a <br />Permit" penalty applies. <br />This is a Repeat (Class 2) Violation. <br />EHD - CUPA Inspection Report IS02 Page 5 of 6 FA0023733 PRO541416 4564779 10/22/2025 <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.