Laserfiche WebLink
N <br /> 7 <br /> ti <br /> SITE <br /> 0 60 120 <br /> SCALE 1"=60' <br /> a <br /> O <br /> �k 0 <br /> O <br /> G � <br /> J <br /> W <br /> VICINITY MAP <br /> NOT TO SCALE <br /> yo <br /> yo SITE PLAN <br /> FOR <br /> yo <br /> RAVINDER GILL , ETAL <br /> 6785 SOUTH EL DORADO STREET <br /> EX. CL <br /> EX. FOG EX. EP - GW o FRENCH CAMP ROAD SAN JOAQUIN, CA 95231 <br /> D TP + SP —¢� <br /> zz <br /> OH S37'53'50"E 255.43' R=423.06' L= <br /> LANDSCAPE 4A172 62' 4-- <br /> TP Gw 3224�., < �� SITE INFO: <br /> OWNER APPLICANT: RAVINDER GILL, ETAL <br /> o 2528 KNOLLWOOD, LANCE <br /> STOCKTON, CA 95206 <br /> S0 <br /> o FUTURE GAS STATION OR TRUCK SALES SITE AREA: 8486 AC 68 SF <br /> 1 .61 ACRES 00, <br /> EX. FOG \ ' APN: 193-070-11 O <br /> _ s PROJECT NAME: CENTRAL VALLEY TRUCKING <br /> 0 <br /> EX. EP v <br /> EX. CL \ PROPOSED PARKING SIZE <br /> \\ \ TRUCK AND TRAILER 113 70'X12' <br /> \� ADA PARKING 1 9'X18 <br /> P P �0j 0\ \ <br /> PROPOSED R-17 <br /> L <br /> DRIVEWAY PASSENGER CAR 2 9'X18' <br /> PROPOSED PAVEMENT 2 �, TRAILER ONLY 3 53'X12' <br /> o 2952. PROPOSED <br /> PATH OF <br /> 0 <br /> P. W FIRE TANK TRAVEL ABBREVIATIONS <br /> & FIRE yo <br /> w I. PUMP 3 \ CL CENTER LINE <br /> HOUSE <br /> \ \ EP EDGE OF PAVEMENT <br /> DESIGN BY y S2'14 56 E 28.54 <br /> 0 �� V,�o EX. EXISTING <br /> OTHERS <br /> FL FOG LINE <br /> Z GW GUY WIRE <br /> GUARD �\ \ P. PROPOSED <br /> SHACK PP \ \ PL PROPERTY LINE <br /> 7.5'X16' �\ PP POWER POLE <br /> 4 2 o P. ST \ 5 SP SERVICE POLE <br /> \ ST SEPTIC TANK <br /> \ \5\ \ TP TELEPHONE POLE <br /> � EX. W <br /> W WELL <br /> 6.87 ACRES �6 ��, N N \ <br /> PROPOSED PAVEMENT oo <br /> 04 i� \ \\ \ PROP. ASPHALT <br /> c , N \ PAVEMENT <br /> �8 o0 oy \ <br /> \ \ \ \ <br /> PP �So, <br /> :o: I I INFILTRATION BASIN O \ <br /> mm 03.22' 6 FT DEPTH <br /> 0.89 ACRES \ \ \ NOTE: PERCOLATION RATE IS BASED ON <br /> 193.28' SLOPE 3: 1 O THERSURRO�NDITWO N ARE <br /> OAECTSS N <br /> 31 2 0 EX. ST 'S' \� <br /> `n \ SUBJECT TO CHANGE BASED ON <br /> o C° 328.37 S37'53'50"E 298.58' \ �Sl'42'20"E 23.20' GEOTECHNICAL REPORT. <br /> 108 -I LANDS APE 367 1' <br /> N37°53'50W 1087.47' \� \ PROPOSED BUILDING INFORMATION <br /> 0// STRUCTURE PROPOSED USE GFA\ (S.F.) HIGHEST OVERALL EMPLOYEES NUMBER FLOOR HEIGHT (EST.) <br /> T <br /> B1 GUARD SHACK 120 1 10'-0" 1 PER DAY <br /> --•,, REVISIONS <br /> �pFESSI(�, LAND <br /> UNAUTHORIZED CHANGES AND USES: QLo�P>t FL �' Y C. kRc�� N0. DESCRIPTION DATE BY WON G ENGINEERS INC. JOB NO.: 4238 6785 S. ELDORADO STREET FRENCH CAMP SHEET <br /> THE ENGINEER PREPARING THIS SITE PLAN WILL NOT BE �� °2 �? JDATE: JUN. 2025 CALIFORNIA <br /> ti� c PLANNING ENGINEERING SURVEYING <br /> RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO 1 ,, ; „7rn 7eoo 4578 FEATHER RIVER DRIVE, SUITE A SCALE: AS SHOWN 1 <br /> OR USES OF THIS PLAN. ALL CHANGES TO THIS PLAN MUST BE ,- &P. Q,30-24o ,� * t�CP 12-3►-Z6 * STOCKTON, CALIFORNIA (209) 476-0011 <br /> IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THIS clviv �\P `r L.S. 7600 DRAWN: NA SITE PLAN OF ONE <br /> SITE PLAN. 11 : WEI <br /> o� �i ,, / DESIGN <br /> OF CA��F �FCI►l. C• w DATE 6 25 2025 R.C.E. 48717 <br /> CHECKED: ZCW FILE 4238 <br />