Laserfiche WebLink
- Implement site-specific procedures for worker protection via engineering controls,work practices,personal protective equipment(PPE),air <br /> I monitoring,decontamination procedures,spill containment,emergency preparedness and response. <br /> - Conduct air monitoring,as appropriate;see Part E,"Air Monitoring,Worker Exposure Monitoring." <br /> PPE program:Specify Levels of Protection and specific PPE to be used for applicable tasks; <br /> o Level D:No respirator,no chemical protective clothing,standard work clothes,basic PPE;(COVID-19 face covers allowed) <br /> o Modified Level D:No respirator,chemical protective clothing as appropriate;(COVID-19 face covers allowed) <br /> I o Level C:Air-purifying respirator,chemical protective clothing as appropriate;consult with Corp.HSE Dept.required. <br /> o Level B:Air-supplied respirator,chemical protective clothing/suit as appropriate;consult with Corp.HSE Dept.required. <br /> o Level A:Fully encapsulating suit,self-contained breathing apparatus(SCBA);Level A prohibited for Geosyntec personnel. <br /> ® FOR SITE WITH CHEMICAL CONTAMINANTS OR WASTE BUT NOT REGULATED BY HAZWOPER <br /> - Workers shall be knowledgeable/aware of chemical hazards thru safety training/orientation and availability of hazard information. <br /> - Implement controls to minimize worker exposure through engineering controls,work practices,PPE,decon,as appropriate. <br /> - Evaluate worker exposure via air monitoring/sampling,as applicable;see Part E,"Air Monitoring,Worker Exposure Monitoring." <br /> ; STORAGE/TRANSPORT OF IDW* ❑Describe site-specific procedures above for spill containment,container handling,as applicable. <br /> Spill/Release Risk: ❑For liquids,provide secondary containment during storage. <br /> ❑Risk of incidental spill/release ❑Segregate incompatible chemicals during storage. <br /> ❑Risk of emergency spill/release i ❑Locate emergency gear(eyewash,fire extinguisher,spill kit,safety signage)near storage area,as applicable. <br /> ❑For incidental spills;spill kit on-site for low-hazard releases(low-flammability/toxicity/quantity/volatility) <br /> 1 *Investigation Derived Waste ; ❑For emergency spills:describe spill/release hazard and response plan/procedure above,and indicate <br /> Emergency response contact in Part B,"Emergency Response and First Aid." <br /> ❑DOT/TDG/IATA-Regulated transport:see D.17."Hazmat/Dangerous Goods Shipping/Transportation." <br /> OFF-SITE MIGRATION OF AIRBORNE ❑Implement controls to minimize hazard migration(dust suppression,covers,foam,etc.). <br /> CONTAMINANTS ❑Community/perimeter air monitoring will be conducted per perimeter air monitoring plan;see E.3"Fence <br /> Line/Perimeter Air Monitoring." <br /> HSE Program Documents:HSESTD-120:Occupational Medical Management Program HSESTD-125:Personal Protective Equipment Program <br /> HSE STD-130:Respiratory Protection Program HSE STD-145:Safety Training Program HSE STD-I50:Globally Harmonized System for Hazard Communication HSE <br /> SOP-301o:Contaminated Site Investigation&Remediation(US-only) HSE SOP-460:Field Site Exposure Monitoring, <br /> HSE SOP-634:Drum Sgmpling,HSE SOP-636:Handling of Uncharacterized Hazardous Waste Containers,HSE SOP 470a Protection from Wildfire Smoke Exposure <br /> D.16. RADIATION HAZARDS(Otherthan Sunlight) ❑ Applicable ® Not Applicable, Not Anticipated <br /> D.17. SHIPPING/TRANSPORTATION HAZMAT/DANGEROUS GOODS Applicable Z Not Applicable, Not Anticipated <br /> MODE(S)OF TRANSPORT: ❑Road ❑Rail ❑Air ❑Sea ❑Inland Waterway LL International <br /> IMPORTANT:Ensure that each individual who will be involved In shipping/transportation of hazardous material is current with required training(awareness,function- <br /> specific,safety,security)in accordance with applicable regulatory authority(DOT,FAA,IATA,TDG),and ensure adherence to applicable regulations. <br /> HSE Program Documents:HSE SOP-235a:Hazardous Materials Shipping US-onl <br /> Site-Specific Notes&Clarifications: <br /> PART E-AIR MONITORING, WORKER EXPOSURE MONITORING <br /> E.1. AIR MONITORING &Applicable ❑ Not Applicable,Not Anticipated <br /> Site-Specific Notes, Claditcations: Volatile Organic Compounds:Air monitoring of worker breathing zone will be performed by Geosyntec personnel while(1) <br /> borings are being advanced,(ii)new monitoring wells are being installed into auger casings,(iii)when grouting to surface,and(iv)when developing new monitoring wells. <br /> A photoionization detector with 11.7 eV lamp, properly calibrated in accordance with manufacturers instructions,will be used for monitoring of volatile organic <br /> compounds(VOCs)in the worker breathing zone during these activities.Worker breathing zone readings will be recorded on no less than a 15-minute frequency. <br /> Background readings will also be recorded and any sustained(longer than 5 seconds)detection above background levels will result in work stoppage so that engineering <br /> controls can be instituted;this will consist of electrically powered fansforthe displacement of VOCsfrom the breathing zone.If sustained(longer than 5 seconds)detections <br /> above background level are still detected after engineering controls are in place then work shall stop and either additional engineering controls shall be put in use before <br /> resuming work activities or the boring will be terminated. <br /> The primary VOC compound of concern is 1,2-dichloropropane(propylene dichloride)which has an OSHA PEL(8-hr TWA)of 75 ppm and a NIOSH IDLH of 400 ppm. <br /> AIR-TESTING PARAMETERS-Select site-specific testing parameters;list associated equipment in Part.C.2,Safety Equipment List <br /> ®VOCs I❑02(Oxygen)-oxygen meter `❑Particulates-total dust meter <br /> ®PID(Photoionization detector): 11.7 eV ❑LEL(Lower Explosive Level)-LEL meter ❑%Methane-methane meter <br /> ❑FID(Flame ionization detector) <br /> I❑H2S(Hydrogen Sulfide)-H2S detector !❑Calibration kit for each parameter <br /> ❑Calorimetric indicator tubes-describe above i❑CO(Carbon monoxide)-CO detector "❑Other: <br /> SUBSTANCE-SPECIFIC(PRE-SET)ACTION LEVELS-Sustained breathing zone action levels sustained general work-area levels for LEL). <br /> Oz 19.5-23% 1 Acceptable to continue work without 02-focused respiratory protection. <br /> Geosyntec° THA Date:6/6/2025 age 1 <br /> Project/Task Name:TR0712/Replacement of Monitoring Wells THA P07 <br /> consultants <br />