My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2026 12:11:47 PM
Creation date
8/27/2025 1:40:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231820
PE
2361 - UST FACILITY
FACILITY_ID
FA0003826
FACILITY_NAME
UNFI GROCERS DISTRIBUTION, INC (STOCKTON)
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1990 N PICCOLI RD STOCKTON 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN AMENDED Environmental Health Department <br /> c o U N ry 11/5/2025 <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: I Facility Address: Date: <br /> UNFI GROCERS DISTRIBUTION, INC (STOCKTO 11990 N PICCOLI RD, STOCKTON I November 05, 2025 <br /> 56 2716(a-e) 2030013 - DO inspections completed at least every 30 days and meet all requirements (TCR 12) <br /> OBSERVATION: <br /> 1) The designated operator(DO)failed to check and note the correct test dates for overfill and secondary containment <br /> testing on the designated operator inspection reports. The correct date for overfill testing is 11/13/24. The correct date for <br /> secondary containment testing is 11/14/24. <br /> 2) The DO inspections for the following months were performed more than 30 days after the previous inspection: <br /> -11/8/24 to 12/9/24 (31 days) <br /> -12/9/24 to 2/5/25 (58 days) <br /> -5/14/25 to 6/14/25 (31 days) <br /> -6/14/25 to 9/10/25 (88 days) <br /> 3) The DO failed to check and note all required items on the visual inspection reports. The incorrect and missing <br /> information included the following: <br /> -Tests that were listed with test dates more than 36 months ago were incorrectly marked as having been conducted in <br /> the past 36 months <br /> -No documentation was attached regarding the L2 (5hp sump)fuel alarm on 2/13/25. The report incorrectly states N/A to <br /> the question asking if the tank top sump alarms were responded to by a service technician. The DO did not inspect the <br /> sump after the alarm. <br /> REGULATION GUIDANCE: During the inspection, the DO shall check that all required testing and maintenance for the <br /> UST system have been completed and document the dates they were done. The DO visual inspections shall be <br /> conducted within 30 days or less of the previous inspection. During the visual inspection, the DO shall check that all <br /> required testing and maintenance for the UST system have been completed and shall check all required items on the <br /> report. <br /> CORRECTIVE ACTION: Ensure that DOs performing inspections at this facility are including all of the required <br /> information on the reports. Ensure that all DO inspections are performed within the required time frames. Ensure that DO <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a Repeat(Class 2)Violation. <br /> 59 2712(b)(1-2) 2030001 - Records of release detection monitoring and maintenance properly maintained (TCR 9d) <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. The missing <br /> records include: <br /> -work orders for the last three years <br /> -5/7/24 MSC (leak detector)test results <br /> -11/13/24 MSC test results <br /> -11/13/24 spill container test results <br /> -11/13/24 overfill prevention test results <br /> -11/14/24 secondary containment test results <br /> -12/5/24 secondary containment test results <br /> -alarm response logs for the L2 fuel alarm on 2/13/25 <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; <br /> (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings <br /> of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings <br /> and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the last <br /> three years on site. Submit copies of any missing work orders and alarm records to the EHD. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 6 of 7 FA0003826 PR0231820 4573447 11/5/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.