Laserfiche WebLink
TYPICAL INSTALLATION <br />'VERY IMPORTANT ' <br />To allow for drainage, Fibrelite recommends that the concrete be sloped away from the top <br />outer edge of the frame (A) a minimum of 1/2" over a 12" distance. Do not expose the top outer <br />• edge of the frame (A) — the concrete pad must be flush with the top outer edge of the frame. • <br />CONCRETE <br />VERY IMPORTANT <br />FRAMES MUST BE INSTALLED FLUSH <br />WITH FINISHED GRADE OR SET SLIGHTLY <br />BELOW FINISHED GRADE TO PROTECT <br />FROM SNOWPLOW DAMAGE <br />it Z 12" 1 <br />Minimum k <br />4 - <br />Maximum Maximum <br />14" I 4-4 ' � <br />4 <br />i00 0 <br />- - - °-ria <br />o g°° c° <br />° °0 0°000 <br />°0°0°° 0 0 00 <br />0 0 00 <br />000 <br />° <br />0000 <br />°° <br />° 0°0° °°° <br />°0 <br />f° <br />°°°°0°00s <br />0000 0 ° <br />°° <br />0 000 0 0 <br />°0° o <br />°° <br />° °° o0 ° <br />g <br />0 0 0 00 00 <br />° <br />°°� o° <br />°° °° <br />° <br />00 <br />0°o0 <br />100 00 00 000 oo°p°a°p0 ,° <br />° <br />° °00°00°°'°°0 <br />° <br />0000 °0p00 <br />0° o ° ° o0 <br />000 ° 000 <br />g <br />0 <br />VERY IMPORTANT <br />The underside of the frame <br />must be adequately <br />supported by concrete. <br />'rZiYl <br />i i I 4 <br />A, <br />0000 a°oo <br />0 o0 OC <br />0 00 ° <br />°O 00 0000°0 °O0 0,.000 <br />o° <br />0000900 <br />0 0 0 c <br />Joint tied with <br />0 <br />00 ° 0° °° ` <br />0 0 24" long x <br />0 <br />, 0°° o0 <br />° 0 12mm dowel at <br />° Q <br />00 000 00 0° 24" c/c. <br />0 0000 0 ° o Half bonded <br />°000 0 <br />° 0a 0°°( <br />° 4°°°°O o°0 00 0 °. <br />° ° o °° <br />°p0 0� °0°000ova 00 <br />° o Concrete reinforced <br />00000 ° O ° <br />° 0 0 ° ° with 2 layers of <br />° °° <br />,0 0 0° ° 0 reinforcement mesh. <br />a of <br />$ 000 °°° <br />Q° ° <br />° 00 <br />°° <br />°° <br />° <br />°o O° <br />°0 °B°oo°,o0°o° ° <br />p <br />00 0 o°00°e°° °°o° <br />° 0°0Co°0°o0 <br />°0o °° <br />00 ° <br />U0 010 <br />00 0 000 <br />�� :'� CONCRETE <br />060 a000 <br />ee <br />PEA GRAVEL <br />FibreTite multipart kit includes watertight platform for (2) 5 -gallon spill buckets, 40" For reference purposes only. This drawing is not a <br />diameter multipart cover, port COVerS, frame and Skirt. specification. Order against product code only. To <br />enable continuous improvement or our products, the <br />designs and specifications are subject to change <br />without notice. <br />Issue: 03/31/2020 1 Page: 4 of 4 1 ®Copyright <br />FIBRELITE <br />rw wT of orw •�nrrr � <br />