Laserfiche WebLink
L---rF---LL-- <br />QSR <br />u <br />N 0°I2' W =50' - <br />PROOPOSIEDD muoLDOMS m 13 <br />NEW <br />6j48= SF. <br />O <br />P-20 <br />rl w <br />(N) CANOPY <br />F-----------------------1�----------------------------------------------- <br />09 P-20 9 12 09 <br />'\- <br />f- - 2 0 O <br />No *5 <br />w <br />O O 1 I/ O O O 0 0 C C O � <br />NEW FUELING <br />*1� 15 16 --------------------- ---------------- <br />s <br />a <br />I� <br />I <br />I <br />I <br />PAYING <br />�--- --------------------- TYP. <br />O P 2 (N) O Q C4 O <br />2,6F 87 1 6C ffig 1 <br />I <br />---------------- - <br />--------J --- ---- - lg> <br />ice -26 <br />N 0°12' W I50' - <br />CURB. GUTTER < SIDEWALK <br />N O R T H T R A C Y B O U L E V A R D <br />F U E L SYSTEM E L E C T R I C A L S I T E P L A N <br />SCALE: P = 10' (USE GRAPHIC SCALE FOR REDUCED PLOTS) <br />0 10 20 40 <br />SITE PLAN DEVELOPED PRIMARILY FROM RECORD DRAWINGS <br />AND PHOTO REVIEW. THIS IS NOT A SURVEY. <br />(CFC 2303.2.1) HEIGHT. THE HEIGHT OF THE EMERGENCY DISCONNECT SWITCH SHALL BE NOT LESS THAN 42 INCHES (106-1 mm) <br />AND NOT MORE THAN 48 INCHES (1219 mm) MEASURED VERICALLY, FROM THE FLOOR LEVEL TO THE ACTIVATING BUTTON. <br />CL <br />CL <br />PANEL P 125 AMP FRAME MAIN LUG ONLY <br />FUELING SYSTEM 120/24OV, 1 PHASE, 3 LOIRE BRANCH CB'S± BOLT -ON, SIZE AS INDICATED <br />TRACY TRIANGLE 30 CIRCUIT, SURFACE MTD. NEMA I INTERRUPTING RATING: 42,000 AIC <br />DESIGNATION <br />11i <br />CKT. BRKRCKT. <br />WIRE <br />AWG <br />SERVES <br />v0 - P <br />LOAD A B LOAD <br />SERVES <br />WIFE <br />AW: <br />BPoGR <br />DESIGNATION <br />CKT. <br />NO. <br />PANEL <br />SPACE <br />AMP <br />POLE <br />AMP <br />POLE <br />PANEL <br />SPACE <br />CKT. <br />NO. <br />1 <br />1 <br />20 <br />2 <br />4*12 <br />DISPENSER 1/2 <br />(SWITCHED NEUTRAL) <br />500 <br />1900 <br />@ <br />1400 <br />SUBMERGED TURBINE PUMP (STP) <br />2 hp REG (0-1) <br />010 <br />30 <br />2 <br />2 <br />2 <br />3 <br />3 <br />0 <br />n <br />1400 <br />1400 <br />4 <br />4 <br />5 <br />5 <br />20 <br />2#12 <br />DISPENSER 3/4 <br />(SWITCHED NEUTRAL) <br />500 <br />1900 <br />1400 <br />SUBMERGED TURBINE PUMP (STP) <br />2 hp SUPER (91) <br />SUBMERGED TURBINE PUMP (STP) <br />1.5 hp DIESEL <br />010 <br />30 <br />2 <br />6 <br />6 <br />_1 <br />0 <br />1-100 <br />1400 <br />1400 <br />1200 <br />8 <br />8 <br />9 <br />920 <br />2 <br />%12 <br />DISPENSER 5/6 <br />(SWITCHED NEUTRAL) <br />500 <br />010 <br />30 <br />2 <br />10 <br />10 <br />11 <br />11 <br />0 <br />1200 <br />1200 <br />12 <br />12 <br />13 <br />13 <br />20 <br />2 <br />012 DISPENSER 1/8 <br />(SWITCHED NEUTRAL) <br />500 <br />1_100 <br />1200 <br />1200 <br />SUBMERGED TURBINE PUMP (STP) <br />1.5 hp E55 <br />012 <br />20 <br />1 <br />14 <br />14 <br />15 <br />15 <br />0 <br />1200 <br />16 <br />16 <br />17 <br />1-1 <br />20 <br />2 <br />#12 SPARE <br />0 <br />0 <br />0 <br />SPACE <br />IS <br />18 <br />19 <br />19 <br />SPARE <br />*12 SPARE <br />0 <br />500 <br />500 <br />ESO <br />012 <br />20 <br />1 <br />20 <br />20 <br />21 <br />21 <br />20 <br />2 <br />0 <br />0 <br />0 <br />SPACE <br />22 <br />22 <br />23 <br />23 <br />SPARE <br />0 <br />1500 <br />1500 <br />INTERCOM <br />"12 <br />20 <br />1 <br />24 <br />24 <br />25 <br />25 <br />20 <br />1 <br />012 <br />MONITOR <br />1,000 <br />1500 <br />500 <br />OVERFILL ALARM <br />X12 <br />20 <br />1 <br />26 <br />26 <br />2-1 <br />2i <br />SPARE <br />0 <br />0 <br />0 <br />SPACE <br />28 <br />28 <br />29 <br />29 <br />20 <br />1 <br />%12 <br />ELLDs <br />500 <br />500 <br />0 <br />SPACE <br />30 <br />30 <br />TOTAL CONNECTED LOAD <br />9,200 <br />-1,200 <br />BUS A: 9,200 vA CONTINUOUS LARGEST CONNECTED TOTAL N.E.G. <br />BUS B: -1,200 VA LOAD: (CL) MOTOR LOAD: (LML) LOAD: COMPUTED LOAD: <br />TOTAL: 16,400 VA C 2,500 VA x 0.25) + ( 2,800 VA x 0.25) + 16,400 VA = 16,400 VA <br />AMPERES 9 120/240v, I PHASE = 14 AMPS <br />p6af IEL H(OVIES <br />L PROVIDE PLASTIC PHENOLIC NAMEPLATE AND TYPED PANEL CIRCUIT DIRECTORY. <br />2. PROVIDE ISOLATED GROUND BUSS FOR ISOLATED GROUND CIRCUIT BREAKER. <br />3. PROVIDE SEAL -OFF FITTINGS FOR ALL CIRCUITS ENTERING PANEL FROM CLASS I, DIV. 2 AREAS. <br />LML <br />LML <br />CL <br />CL <br />FUEL SYSTEM ELECTRICAL KEYNOTES 0 <br />I. INSTALL NEW FUEL SYSTEM CONTROLS. SUPPLY AND INSTALL NEW FUEL SYSTEM RELATED PANELS, WIREWAY6, CONDUIT, CONDUCTORS, 5EALOFF5, ETC., AS <br />REQUIRED, PER MNFR. RECOMMENDATIONS. REFER TO AND COORDINATE W/ THE REQUIREMENTS OF THE ARCHITECTURAL AND ELECTRICAL SHEETS. IF <br />CONFLICTS OCCUR BETWEEN THESE AND OTHER DRAWINGS NOTIFY THE ARCHITECT / ENGINEER. <br />2. NEW (N) MONITORING PANEL. INSTALL NEW MONITORING COMPONENTS PER MNFR. RECOMMENDATIONS. <br />3. (N) EMERGENCY SHUTOFF (E.6.0.) W/ 3/4 C.. SEE ALSO FUEL SYSTEM SITE PLAN. INSTALL SIGNS(&) PER CFC 2303.2. MUSHROOM PUSH-BUTTON W/ <br />PLEXIGLAS COVER COR NEMA 3R ENCL.). CONNECT TO MAIN SHUNT TRIP CIRCUIT, WIRE PER MNFR. REQUIREMENTS. ((3) #12ga. - MIN., SEE KEYNOTES 12, 15) <br />4. (N) 3/4" C. FOR STP (SUBMERGED TURBINE PUMP) W/ #10'6 AND #10 GNI--)., (MIN.) VIA WIREWAY. (POWER (4) #10ga., ) <br />5. (N) 1" C. HOMERUN TO WIREWAY FOR ELECTRONIC LINE LEAK DETECTOR, SUMP FLOAT SWITCH, VACUUM/HYDRO SENSORS, SUMP MINI -HYDRO SENSOR AND <br />TANK GAUGE PROBE. ((8) 2#18ga. SND. CABLE) <br />6. (N) 3/4" C. HOMERUN TO WIREWAY W/ 3/4" LOOPED (NO LOOP AT DIESEL) FOR HYDROSTATIC SENSOR, SUMP FLOAT SWITCH AND SUMP MINI -HYDRO <br />SENSORS. (INTERSTITIAL (1) 2#18ga. SHD, CABLE, FILL (2) 2#18ga. SHD. CABLE) <br />-1. (N) 3/4" C. HOMERUN TO WIREWAY FOR DISPENSER N.V., TYP.. WIRE PER MNFR. REQUIREMENTS. (3+0'5 (5) #12ga., (2) #14ga. TWISTED - FOR 3+115 ADD (1) #12 ga.) <br />S. (N) 3/4" C. HOMERUN TO WIREWAY FOR MONITORING L.V., TYP.. WIRE PER MNFR. REQUIREMENTS. (MONITOR (3) 2#18ga. SND. CABLE) <br />9. (N) 3/4" C. HOMERUN TO WIREWAY FOR DISPENSER INTERCOM PLUS GAT-5/ETHERNET FOR EMV-READY CARD SYSTEM, TYP.. WIRE PER MNFR. <br />REQUIREMENTS. (INTERCOM MIN. (2) #14ga. TWISTED, (2) #16ga.) <br />10. (N) NEW 3/4" C. FROM VENT CONTAINMENT / MONITORING TO WIREWAY, W/ SEAL -OFFS AS REQUIRED. (SUMP - (2) 2#18ga. SHD. CABLE, <br />(CVP - (1) 2#18ga. SND. CABLE) <br />Il. (N) NEW 3/4" C. TO WIREWAY FOR OVERFILL ALARM. WIRE PER MNFR. REQUIREMENTS. ((4) #12ga.) <br />12. HOMERUN CIRCUIT, TYPICAL. MINIMUM (2) #12'6 AND (1) #12 GNI--). IN 3/4" C. W/ MAXIMUM (3) HOMERUN CIRCUITS PER CONDUIT. NUMBER OF ARROWHEADS <br />INDICATES NO. OF HOMERUN CIRCUITS. BRANCH CIRCUITS GREATER THAN 15 FT. TO FIRST LIGHT FIXTURE OR OUTLET SHALL BE MINIMUM #10 AWG. <br />INCREASE WIRE AND CONDUIT SIZE PER MNFR. AND/OR CODE REQUIREMENTS. <br />13. ALL CONDUITS AT TRAFFIC AREAS TO BE BURIED A MIN. OF 24" (12" AT NON -TRAFFIC AREAS). <br />14. LOCATE SEAL -OFF FITTINGS PER CEC 514 AND HAZARDOUS LOCATION SPECIFICATIONS, THIS SHEET, FOR CIRCUITS TO DISPENSING AREA AND <br />UNDERGROUND FUEL TANKS, AS APPLICABLE. <br />15. INSTALL (CONSULT OWNER PROVIDED EQUIPMENT LIST) AND/OR PROVIDE AND INSTALL ADDITIONAL SYSTEM COMPONENTS, INCLUDING BUT NOT LIMITED <br />TO CONDUITS, HIGH 4 LOW VOLTAGE CONDUCTORS FOR POWER, MONITORING AND COMMUNICATIONS (INTERCOM 4 CONTROL), J -BOXES, 5EALOFF5, ETC. AS <br />REQUIRED TO PROVIDE A COMPLETE, WORKABLE SYSTEM PER MNFR. AND CODE REQUIREMENTS. INSURE THAT CONDUCTORS MATCH MNFR'&. REQS. FOR <br />PURPOSE AND CONDUIT LENGTHS. <br />16. CONDUIT RUNS ARE INTENDED AS SCHEMATIC, AND MAY BE EXAGGERATED FOR DRAFTING CLARITY. FIELD CONDITIONS AND STANDARD PRACTICES <br />MAY INDICATE DIFFERENCES AND ARE EXPECTED. <br />HAZARDOUS LOCATION SPECIFICATIONS <br />A. FUEL SYSTEM CONTRACTORS AND INSTALLERS ARE EXPECTED AND REQUIRED TO HAVE CURRENTLY REQUIRED EQUIPMENT MANUFACTURERS' <br />CERTIFICATIONS AND APPROVALS FOR INSTALLATION OF ALL OF THE FUEL SYSTEM RELATED EQUIPMENT AND WORK, INCLUDING ELECTRICAL <br />COMPONENTS, AND TO PROVIDE A COMPLETE, WORKABLE SYSTEM PER MNFR. AND CODE REQUIREMENTS. <br />B. PROVIDE EXPLOSION PROOF JUNCTION BOX AND SEAL -OFF FITTINGS PER ARTICLE 514 OF THE GEC FOR HAZARDOUS LOCATIONS. <br />C. ALL CONDUIT AND WIRING TO FUEL DISPENSERS AND SUBMERSIBLE PUMPS SHALL BE INSTALLED AND USED IN ACCORDANCE WITH FLAMMABLE AND <br />COMBUSTIBLE LIQUIDS CODE NFP,4 30 AND APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE CALIFORNIA ELECTRIC CODE ARTICLE 514, MOTOR <br />FUEL DISPENSING FACILITIES, INCLUDING THE FOLLOWING: PROVIDE EXPLOSION PROOF/SEAL-OFF FITTINGS ON ALL POWER SUPPLY LINES LOCATED AT <br />FUEL DISPENSERS, SUBMERSIBLE PUMPS AND ANY OTHER ELECTRICAL EQUIPMENT LOCATED IN A 20' RADIUS OF THE GASOLINE FUEL DISPENSER ISLAND. <br />AN AREA PER FIGURE 514.3 OF THE CEC IS DEFINED AS A HAZARDOUS LOCATION WITHIN A 20' RADIUS FROM THE END OF EACH DISPENSER. ALL <br />ELECTRICAL EQUIPMENT AND WIRING WITHIN THIS AREA SHALL BE PER CEC 514. <br />D. GEC 541.9 SEALING (OF DISPENSERS) - A LISTED SEAL (EXPLOSION PROOF SEAL -OFF FITTING) SHALL BE PROVIDED IN EACH CONDUIT RUN ENTERING OR <br />LEAVING A DISPENSER OR ANY CAVITIES OR ENCLOSURES IN DIRECT COMMUNICATIONS THEREWITH. THE SEALING FITTING OR LISTED EXPLOSIONPROOF <br />REDUCER AT THE SEAL SHALL BE THE FIRST FITTING AFTER THE CONDUIT EMERGES FROM THE EARTH OR CONCRETE. (B) AT BOUNDARY- ADDITIONAL SEALS <br />SHALL BE PROVIDED IN ACCORDANCE WITH 501.15. SECTIONS 501.15(A)(4) AND (5)(2) SHALL APPLY TO HORIZONTAL AS WELL AS TO VERTICAL BOUNDARIES <br />OF THE DEFINED GLASS I LOCATIONS. <br />E. PROVIDE EXPLOSION PROOF/SEAL-OFF FITTINGS AT THE POINT OF CONDUIT STUBUP ENTRANCE (AT PANELBOARD) INTO THE SERVICE BUILDING FOR ALL <br />POWER SUPPLY CONDUITS TO FUEL DISPENSERS, SUBMERSIBLE PUMPS AND OTHER ELECTRICAL EQUIPMENT LOCATED IN THE ABOVE DEFINED <br />HAZARDOUS LOCATIONS. <br />F. ALL BELOW GRADE CONDUIT RUNNING THROUGH (ENTERING OR LEAVING - THEN THE ENTIRE CONDUIT RUN SHALL BE RGS) THE GLASS 1 DIVISION 1 <br />HAZARDOUS LOCATION AS DESCRIBED ABOVE AND AS DEFINED PER CEC ARTICLE 514 SHALL BE RGS. RIGID NON-METALLIC CONDUIT (PVC) MAY ONLY <br />BE USED AS LONG AS THE PROVISIONS OF NEC ARTICLE 514.8 EXCEPTION NO. 2 ARE STRICTLY ADHERED TO INCLUDING THE REQUIREMENTS FOR AN <br />EQUIPMENT GROUNDING CONDUCTOR IN THE RIGID NON-METALLIC CONDUIT AND THE EQUIPMENT GROUNDING CONDUCTOR MUST BE BONDED TO THE <br />EXPLOSION -PROOF RACEWAY SYSTEM INSIDE THE DISPENSER (THIS MAY BE ACCOMPLISHED BY TERMINATING THE EQUIPMENT GROUNDING CONDUCTOR <br />ON THE GROUND SCREW PROVIDED IN THE JUNCTION BOX). WHERE RIGID NON-METALLIC CONDUIT IS USED IT SHALL BE BURIED A MINIMUM OF 2 FEET <br />BELOW EARTH AND THREADED RIGID METAL CONDUIT SHALL BE USED FOR THE LAST 2 FEET OF THE UNDERGROUND RUN TO EMERGENCE OR POINT OF <br />CONNECTION TO THE ABOVE GROUND RACEWAY. <br />G. EACH CIRCUIT LEADING TO OR THROUGH A DISPENSING PUMP SHALL BE PROVIDED WITH A SWITCH TO DISCONNECT SIMULTANEOUSLY FROM THE SOURCE <br />OF SUPPLY ALL CONDUCTORS OF THE CIRCUIT INCLUDING THE GROUNDED CONDUCTOR. <br />H. THE METAL PORTION OF DISPENSING PUMPS, METAL RACEWAYS AND ALL NON-CURRENT CARRYING METAL PARTS OF ELECTRIC <br />EQUIPMENT, REGARDLESS OF VOLTAGE SHALL BE GROUNDED AS PROVIDED IN GEC ARTICLE 250. <br />I. CONDUCTORS SHALL BE: THWN WIRE, GAS 4 OIL RESISTANT, AND BELDEN (OR EQUAL) 88160 MULTI -CONDUCTOR, SINGLE <br />PAIR CABLE (FOR 2#I0GA. SND. CABLE). <br />�l <br />PET=6 <br />OF 9 'PET' SHEETS <br />U <br />Z <br />11i <br />W� <br />V <br />w <br />Z <br />m <br />V' <br />Y <br />aZJ <br />LdN <br />Ld <br />O Lr <br />Z <br />x z c(3 LLI C14 <br />O <br />Ill<mv <br />a <br />L4 <br />�Z <br />Y" <br />OL <br />U <br />(s) <br />�wqm <br />(s)LLI <br />w <br />D <br />PET=6 <br />OF 9 'PET' SHEETS <br />111 (p <br />Zit) w� <br />W <br />W� <br />V <br />wmv� <br />'q <br />N <br />Y <br />aZJ <br />W W <br />� O m <br />-4 <br />.j <br />LLI X <br />ppm <br />� <br />� <br />U <br />�Z <br />Y" <br />---) <br />U <br />�V <br />�wqm <br />N <br />w <br />(3u <br />o <br />_ <br />@ <br />o <br />o) <br />n <br />w <br />T11-00% <br />Z <br />w <br />U <br />PET=6 <br />OF 9 'PET' SHEETS <br />w <br />W <br />oo�Z <br />Q) <br />�Q <br />LLI <br />N <br />Y <br />aZJ <br />Z <br />QW <br />LL <br />A O <br />-1 <br />Cl <br />U <br />n <br />LL, <br />,L <br />PET=6 <br />OF 9 'PET' SHEETS <br />z <br />U <br />W <br />oo�Z <br />Z <br />Y <br />aZJ <br />Z <br />QW <br />LL <br />A O <br />-1 <br />LLI <br />PET=6 <br />OF 9 'PET' SHEETS <br />z <br />U <br />z <br />U <br />z <br />U <br />z <br />U <br />LLI <br />LLI <br />CA <br />N <br />a) <br />N <br />N <br />n <br />o <br />o <br />@ <br />o <br />PET=6 <br />OF 9 'PET' SHEETS <br />