Laserfiche WebLink
ELectronic <br /> SUPPORTS MANIFOLDED LINES <br /> One transducer per manifolded line is required <br /> THE RED JACKET STP THE RED JACKET STP <br /> STPs and Piping <br /> Supports a wide-range of pump and pipe types. Utilizes Swiftcheck Valve on early generation Red Jacket Standard STPs. <br /> For further details,click here for the Line Leak Application Guide <br /> Line Leak Transducer Specifications <br /> Operating Temperature -25•F to+130°F <br /> Unleaded Gasoline <br /> Leaded Gasoline es sel(Up to 6100) <br /> Kro <br /> • 5%Methanol Kerosene <br /> Compatible Fuel Types Jet Fuel <br /> Up to 100%Ethanol Aviation Gasoline <br /> 15%MTBE DEF <br /> Diesel <br /> Line Flow Rate 120 GPM Max w/Swiftcheck Valve <br /> Operating Range 0—70 PSI <br /> Proof Pressure 200 PSI <br /> Maximum Vertical Pipeline Height Above Transducer 11 ft <br /> Minimum Pump Output Pressure 23 PSI <br /> Maximum Volume of Fuel Monitored TLS-450PLUS—1178 gallons <br /> TLS-350—212 gallons <br /> TLS-450PLUS Line Leak Digital Transducer Ordering <br /> 859080-001 Digital Pressurized Line Leak Detector(DPLLD)without SwiftCheck Valve,UL <br /> 859080-002 Digital Pressurized Line Leak Detector(DPLLD)with SwiftCheck Valve,UL <br /> 332812-001 16 Input Universal Sensor Module(USM) <br /> 332813-001 5 Universal Input/Output Interface Module(UIOM),Relay Control and Input Signal Monitoring <br /> 332972-007 Ultimate Testing:Digital Line Leak Detection* <br /> 332972-008 Risk Management:Digital Line Leak Detection* <br /> 332972-009 Base Compliance:Digital Line Leak Detection* <br /> 1 Line Leak Analog Transducer Ordering Information <br /> DescriptionPart Number 848480-001 Pressurized Line Leak Detector(PLLD)without SwiftCheck Valve,UL <br /> 848480-003 Pressurized Line Leak Detector(PLLD)with SwiftCheck Valve,UL <br /> 330843-001 6 Input Pressurized Line Leak Interface for use with PLLD Module <br /> 330374-001 3 Output Pressurized Line Leak Controller <br /> 330160-010 Ultimate Testing:Pressurized Line Leak Detection(PLLD)* <br /> 330160-060 Risk Management:Pressurized Line Leak Detection(PLLD)* <br /> 330160-050 Base Compliance:Pressurized Line Leak Detection(PLLD)* <br /> *One per system required for precision line leak detection capability. <br /> NOTE:The TLS-350 analog transducer is not compatible with the TLS-450PLUS ATG. <br /> 125 Powder • - / ••Box 2003Simsbury, 06070 O 1 1 --•- ••• 60 •Rev.A <br /> All information contained in this document is subject to change without notice. VEEDER-ROOT <br /> 1.888.561.7942 -•' • <br />