My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9036
>
2300 - Underground Storage Tank Program
>
PR2500477
>
INSTALL_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2026 10:51:56 AM
Creation date
8/28/2025 4:19:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2024
RECORD_ID
PR2500477
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0004289
FACILITY_NAME
ARCO 07193
STREET_NUMBER
9036
STREET_NAME
THORNTON
STREET_TYPE
RD
City
Stockton
Zip
95209
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
9036 THORNTON RD Stockton 95209
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA N J a A Q U I N Environmental Health Department <br /> COUNTY <br /> I. MONITORING: All monitoring equipment must be listed in the State Water Resources Control Board <br /> Division of Clean Water Program Local Guidance Letter 113. <br /> Check Code <br /> Box Section <br /> 23 All secondary containment units (e.g. tank annular spaces, secondary piping, sumps, <br /> 2632CR under-dispenser containment, etc.) monitored for leaks using approved electronic leak <br /> 2636(f) detections stems. <br /> Electronic monitoring sensors located at the following points: <br /> ° At the bottom of the interstitial space of each secondarily-contained tank, <br /> positioned as near as possible to the bottom of the tank. <br /> Manufacturer Veeder-Root Model 794380-304 <br /> ° In each collection sump, positioned as near as possible to the bottom of the <br /> collection sump. Additionally, in any sump acting as secondary containment for <br /> unused tank openings which connect to the primary space. <br /> Manufacturer Veeder-Root Model 794380-208/Hydrostatic-304 <br /> 23 CCR <br /> 2632 <br /> 2630(d) ° In dispenser pans which do not drain into secondary containment piping. (Note: <br /> A mechanical switch which triggers a shear valve may be substituted but this <br /> system will not qualify for the annual line tightness test exemption under 23 CCR <br /> 2636(g)). <br /> Manufacturer Veeder-Root Model 794380-208/Hydrostatic-304 <br /> l//Along secondarily-contained pipe runs which do not meet the 1/8 inch-per-foot <br /> slope requirement, positioned in the depressed or low-lying areas. <br /> Manufacturer Veeder-Root Model 794380-208 <br /> 23 CCR Automatic line leak detectors installed to monitor underground pressurized piping. <br /> 2636(f) <br /> HSC Manufacturer Veeder-Root Model 848480-001 <br /> 25290.1 h <br /> 25290.2 <br /> Alarm panel provides both audible and visual alarms. It is located in a protected area <br /> 23 CCR and within sight and hearing distance of on-site personnel and hard-wired to a <br /> 2632(c)(2)(B) dedicated circuit. <br /> Manufacturer Veeder-Root Model TLS-450 Plus <br /> J. OTHER COMPONENT INFORMATION: <br /> COMPONENT IFMANUFACTURER I MODEL [COMPOSITION <br /> SUMP CSI DWT-6 TYPE II D/W Fiberglass <br /> UNDER-DISPENSER <br /> CONTAINMENT Bravo B-9250-D36 F/W Fiberglass <br /> F-07RS-0-DF <br /> PENETRATIONS Bravo F-10RS-0-DF D/W Fiberglass <br /> 8 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.